DC Inverter Air
mode, namely, the air conditioner system only performs the Blowing state under the cooling mode.
Annex 3 Parameter Table of Temperature Sensor
(temperatures of room temperature sensor and pipe temperature sensor are the same) (10K,25
℃
)
Celsius
Resistance
Fahrenh
Celsius
Resistance
Fahrenh
Celsius
Resistance
Fahrenh
‐20
115.2660
‐4.0
26
9.5507
78.8
72
1.5367
161.6
‐19
108.1460
‐2.2
27
9.1245
80.6
73
1.4848
163.4
‐18
101.5170
‐0.4
28
8.7198
82.4
74
1.4350
165.2
‐17
96.3423
1.4
29
8.3357
84.2
75
1.3870
167.0
‐16
89.5865
3.2
30
7.9708
86.0
76
1.3111
168.8
‐15
84.2190
5.0
31
7.6241
87.8
77
1.2908
170.6
‐14
79.3110
6.8
32
7.2946
89.6
78
1.2542
172.4
‐13
74.5360
8.6
33
6.9814
91.4
79
1.2133
174.2
‐12
70.1698
10.4
34
6.6836
93.2
80
1.1739
176.0
‐11
66.0898
12.2
35
6.4002
95.0
81
1.1360
177.8
‐10
62.2756
14.0
36
6.1306
96.8
82
1.0996
179.6
‐9
58.7079
15.8
37
5.8736
98.6
83
1.0645
181.4
‐8
56.3694
17.6
38
5.6296
100.4
84
1.0307
183.2
‐7
52.2438
19.4
39
5.3969
102.2
85
0.9982
185.0
‐6
49.3161
21.2
40
5.1752
104.0
86
0.9668
186.8
‐5
46.5725
23.0
41
4.9639
105.8
87
0.9366
188.6
‐4
44.0000
24.8
42
4.7625
107.6
88
0.9075
190.4
‐3
41.5878
26.6
43
4.5705
109.4
89
0.8795
192.2
‐2
39.8239
28.4
44
4.3874
111.2
90
0.8525
194.0
‐1
37.1988
30.2
45
4.2126
113.0
91
0.8264
195.8
0
35.2024
32.0
46
4.0459
114.8
92
0.8013
197.6
1
33.3269
33.8
47
3.8867
116.6
93
0.7771
199.4
2
31.5635
35.6
48
3.7348
118.4
94
0.7537
201.2
3
29.9058
37.4
49
3.5896
120.2
95
0.7312
203.0
4
28.3459
39.2
50
3.4510
122.0
96
0.7094
204.8
5
26.8778
41.0
51
3.3185
123.8
97
0.6884
206.6
6
25.4954
42.8
52
3.1918
125.6
98
0.6818
208.4
7
24.1932
44.6
53
3.0707
127.4
99
0.6186
210.2
8
22.5662
46.4
54
2.9590
129.2
100
0.6297
212.0
9
21.8091
48.2
55
2.8442
131.0
10
20.7184
50.0
56
2.7382
132.8
11
19.6891
51.8
57
2.6368
134.6
12
18.7177
53.6
58
2.5397
136.4
13
17.8005
55.4
59
2.4168
138.2
14
16.9341
57.2
60
2.3577
140.0
15
16.1156
59.0
61
2.2725
141.8
16
15.3418
60.8
62
2.1907
143.6
17
14.6181
62.6
63
2.1124
145.4
18
13.9180
64.4
64
2.0373
147.2
19
13.2631
66.2
65
1.9653
149.0
20
12.6431
68.0
66
1.8963
150.8
21
12.0561
69.8
67
1.8300
152.6
112
/
113
Summary of Contents for ITCA-60CHRA/DV3I
Page 1: ...Technical Manual for DC Inverter Air Conditioner 1 113...
Page 13: ...DC Inverter Air 1 4 Electrical Wiring Diagram 13 113...
Page 14: ...DC Inverter Air 1 5 Air Velocity and Temperature Distributions Airflow velocity 14 113...
Page 22: ...DC Inverter Air 22 113...
Page 28: ...DC Inverter Air 2 3 Service Space 2 4 Wiring Diagrams 28 113...
Page 41: ...DC Inverter Air 3 2 Wirin g Diagra ms 41 113...
Page 42: ...DC Inverter Air A irflow velo city Discharge angle 60 FLOOR 42 113...
Page 43: ...DC Inverter Air Airflow velocity Temperature 43 113...
Page 64: ...DC Inverter Air 7 2 Electrical Wiring Diagram 2 1 TCA 36HRA DV 64 113...
Page 65: ...DC Inverter Air 2 2 TCA 48H RA DV3 TCA 60HRA DV3 65 113...
Page 66: ...DC Inverter Air 2 2TCA 18HRA DVO TC A 24HRA DVO 66 113...
Page 82: ...DC Inverter Air 82 113...