TCL Multimedia Technology Holding CRT BU R&D Center
Chassis Name
NX56-AP&NX56B-AP
Serial No.
Issued on
2008-01-18
Page
Page 14 of 17
Updated on
2009-04-24
Version
4.0
2.
Enter P-Mode, press key “5” to select page “5”. Set the corresponding item to require
value. See below table 3.7.2 for detailed description.
Table 3.7.2: Producing parameter setup and option page “5”
OSD menu
Default Value
Description
Remark
0=EHT tracking only on vertical
Track. Mode
1
EHT tracking mode
1=EHT tracking on vertical and EW
VX Normal
25
4:3 mode vertical zoom
Don’t adjust, use default
VX Compr.
0
16:9 mode vertical zoom
Don’t adjust, use default
WBF
5
Wide blanking start
Don’t adjust, use default
WBR
8
Wide blanking end
Don’t adjust, use default
GET OFFSET
0
Get offset
See below description for detailed
ColdRC
61
Recommended value= “61”
ColdGC 56
Cold color temperature R
and G cut-off offset
Recommended value= “56”
ColdRD
61
Recommended value= “61”
ColdGD 66
Cold color temperature R
and G drive offset
Recommended value= “66”
WarmRC
72
Recommended value= “72”
WarmGC 71
Warm temperature R and G
cut-off offset
Recommended value= “71”
WarmRD
65
Recommended value= “65”
WarmGD 64
Warm color temperature R
and G drive offset
Recommended value= “64”
Description for AUTO OFFSET and GET OFFSET:
The
“GET OFFSET”
can use to make the EEPROM copy by PE engineer. When the
PAL and NTSC geometry adjustment had finished, trigger the “GET OFFSET” from “0” to
“1” to store the geometry offset datum between PAL and NTSC in EEPROM.
On producing, these geometry offset datum can use to easy the NTSC geometry
adjustment. When finished the PAL geometry adjustment, trigger the “AUTO OFFSET”
from “0” to “1”, then the
geometry adjustment of NTSC signal will finish automated. If now
the geometry of NTSC signal is look good, it not needed to adjust the geometry of NTSC
signal any more.
3.
Enter P-Mode, press key “6” to select page “6”. Set the corresponding item to require
value. See below table 3.7.3 for detailed description.
Table 3.7.3: Producing parameter setup and option page “6”
OSD menu
Default Value
Description
Remark
AGCT
32
AGC take over point
AGC
0
AGC take over point indicate
See section “3.2 RF AGC alignment”
for detailed.
OIF
32
IF demodulator offset
Don’t adjust, use default