14
TYPICAL SETUPS
Digital Setup
- M300 as Insert
This setup is ideal if you are using the M300
as a digital insert effect on your harddisk
recording system.
This setup requires that you are using an
I/O card with S/PDIF In/Out.
• Select Serial Routing by leaving the
ROUTING switch on the rear panel in Out
position.
• Connect the M300 S/PDIF digital Out to the
Digital Input on your soundcard.
• Connect the Digital Out on your soundcard to
the Digital In on the M300.
• Set your Soundcard to act as Master clock.
There can be different names for this setting
but “Internal Clock”, “Internal Sync” or
“Master“ are commonly used phrases.
(This is probably setup via you harddisk
recording program. Please refer to owners
manual)
• Press the DIGI IN button on the M300.
• If the DIGI IN LED is green, the M300 is
locked correctly on the Digital Input signal.
• If the LED is flashing Digital In is selected but
no digital signal is received within 5 seconds
or the signal is corrupt.
The M300 automatically returns to internal
clock and analog operation but will continue
to look for digital signal and the DIG IN LED
on the front panel will keep blinking.
Check cables and make sure that your
Soundcard is set as Master.
• Once setup you can use the M300 as a
plugin on your harddisk recording mixer.