Signal Flow - 3-band mode
This is a schematic overview of the signals flow through the algorithm in 3-band mode. As illustrated - the signal first
passes the 4-band parametric EQ. The signal is then split into lo-, mid- and hi-bands for individual compression.
Cross-over frequencies between the bands are set by the selected Source type.
After the Make-up Gain section, the signal passes the Limiter.
Signal Flow - Full-band mode
The signal flow in Full-band mode is similar to 3-band mode. The difference lies solely in the Full-band compression as
opposed to the split-filter and 3 compression bands found in 3-band mode.
Parametric
EQ
Make-up
Gain
Limiter
Comp
In Level
Comp/
De-Esser
Parametric
EQ
Comp/
De-Esser
Make-up
Gain
Limiter
3 band
Split
Filter
+
Mid
Lo
Comp
In Level
Hi
FABRIK C LIVE