6
QUICK SETUP REFERENCE
......and setup the following:
•
Rename
all EQ Stations with different names such as;
EQS#1, EQS#2 etc. In EQ Station networks all units
must have unique names.
•
Set Cluster.
The Cluster defines a group of EQ Stations.
There can be more Clusters in a network. Per default the
Cluster is set to set to “A” - for this example, - leave all
EQ stations at this setting.
• Set Device Number
on all EQ Stations. This number
specifies in which order channels will be assigned to
Cluster locations when you later perform a Cluster Auto
Setup - see example on adjacent page.
•
Set IP address.
All EQ stations must have unique I/P
addresses. The default address in the EQ Station is set
to 192.168.1.100. Leave the first EQ Station at that
address. Change the next to 192.168.1.101 - and so
forth.
•
The Subnet mask
is per default set to 255.255.255.0
and should only be changed if you at a later stage
connect your EQ stations to a PC network that uses a
different Subnet mask.
- for the example on the adjacent page, - leave all EQ
Stations at 255.255.255.0.
Important!
You MUST ALWAYS reboot your EQ Stations after you
have changed:
• Name
• Device Numbers
• IP Addresses
• Subnet mask
..... before performing the Auto Setup described in the
following.
Network of 2 or more EQ Stations
When a network of two or more EQ Stations is build all
channels must be assigned to a location in the Cluster
map found at the Global page.
A convenient “Auto Assign” function makes it very
easy to make a Cluster setup. Specific re-routing of
channels can always be made later.
• Connect power and audio connections according to the
previously described Setups.
• Connect also all EQ Stations via the RJ45 Link
connections using cross-coupled ethernet cables.
• Power on ALL units.
• On each unit, one by one: Go to the Setup-Network and
Device page....