36
frame - sysTem - maIn - mIDI
Normal mode
In Normal mode all banks can be accessed for program
changes. Bank selection is done via Ctrl 0 (MSB) and
Ctrl 32 (LSB):
• Controller 0 must be set to 0 in all cases.
• Controller 32 value must match the bank number you
wish to address according to the table below.
Ctrl 32 value 0 - F1:
Loudness, Stereo
Ctrl 32 value 1 - F2:
Loudness, Multichannel
Ctrl 32 value 2 - F3:
Reserved
Ctrl 32 value 3 - F4:
Format Conversion
Ctrl 32 value 4 - F5:
Reserved
Ctrl 32 value 5 - F6:
Delay and EQ
Ctrl 32 value 6 - F7:
Reserved
Ctrl 32 value 7 - F8:
Monitor and Lineup
Ctrl 32 value 8 - F9:
Reserved
Ctrl 32 value 9 - F10:
Metering
Ctrl 32 value 10 - F11:
Reserved
Ctrl 32 value 11 - F12:
Reserved
Ctrl 32 value 12 - F13:
Reserved
Ctrl 32 value 13 - F14:
Reserved
Ctrl 32 value 32 -
User bank
Ctrl 32 value 64 -
Card Bank 1
Ctrl 32 value 65 -
Card Bank 2
Ctrl 32 value 66 -
Card Bank 3
- - - - -
Ctrl 32 value 73 -
Card Bank 10
Example:
You wish to recall preset 5 from the Loudness, Stereo
bank. According to the table above:
• Set Ctrl 0 to “0” and Ctrl 32 to “0” and send program
change no 5.
SysEx Device ID
Range: 0 to 126
Select SysEx ID for the Mainframe.
MIDI Rate
Range: Normal or 19.2
This parameter sets the Baud Rate / MIDI transfer rate.
The default setting is “Normal”. However, “19.2” may be
better suited for external master control programs as found
in broadcast stations.
MIDI Setup Page
Introduction
MIDI Channels
To recall presets for Scene, Routing and Engines 1 to 4
you must first setup individual MIDI channels for these
categories.
In the example above MIDI channels 1 to 4 ar set up for
Engines 1 to 4 respectively and channel 5 to access Scene
presets and channel 6 to access Routing presets.
Bank Mode
The Bank mode settings determine the destination bank
of the received program change on the specified MIDI
channels.
Normal mode:
This mode requires that the external sending MIDI device
can send both Controller 0 and 32 in addition to MIDI
program changes. This is an essential feature to recall
presets from a device holding more than 128 preset
locations. (see table in next column for details)
Factory and User mode:
These modes will force any incoming program change
to access either Factory or User banks directly and are
typically used if your sending MIDI device cannot send
Controllers 0 and 32 as described above.