background image

TC1720

 (Optional Dual Optics)

User's Manual

Rev. 1.4

-8-

Chapter 2 - Installation

Unpacking the Unit

Before unpacking any equipment, inspect all shipping containers for evidence of external damage caused
during transportation.  The equipment should also be inspected for damage after it is removed from the
container(s).  Claims concerning shipping damage should be made directly to the pertinent shipping agencies.
Any discrepancies should be reported immediately to the Customer Service Department at TC Communi-
cations, Inc.

Equipment Location

The TC1720 should be located in an area that provides adequate light, work space, and ventilation.  Avoid
locating it next to any equipment that may produce electrical interference or strong magnetic fields, such as
elevator shafts, heavy duty power supplies, etc. As with any electronic equipment, keep the unit from
excessive moisture, heat, vibration, metallic particles and freezing temperatures. Installation Procedure
Summary

Installation Procedure Summary

The TC1720 is designed for quick and easy installation.  Before installing, however, make sure all DIP
switches are in the up ("Off") position and double-check the polarity at the DC power's terminal block
connector.  The installation procedure is as follows:

1. Connect your DTE/DCE Device to the DB37 Connector: 

Check the Pin Assignments on page 3

and verify your application's data rate. Shielded cable is recommended.

2. Connect the optic cables:

 Connect the local unit's optic "TxA" to the remote unit's optic "RxA".

Connect the local unit's optic "RxA" to the remote unit's optic "TxA."  (do the same for "TxB" and "RxB"
on Dual Optics Models).

3. Connect the power plug:

 The plug can be connected into either power terminal "A" or "B" (check for

proper polarity).  The unit is equipped with power redundancy.  By plugging a second power supply to
the spare power terminal, power redundancy is enabled.  Verify that the power "A" and/or "B" LED is
illuminated.

4. Turn "On" your device:

 If your device is a DTE/DCE device, the "TxD" & "TxClk" LEDs on the local

unit should be illuminated, meaning the signal is being transmitted. On the remote unit, the "RxD" &
"RxClk" LEDs should be illuminated, meaning the signal is being received.

5. Check the "Rx-A" LEDs: 

When a good optic signal is received, the "Rx-A" LED on the corresponding

unit should illuminate.  (Check "Rx-B" LED when "Optic TxB" and "Optic RxB" are  in use.  Dual Optics
model only).

Summary of Contents for TC1720

Page 1: ...fica tion TC Communications Inc reserves the right to change or modify the contents of this manual at any time without prior notification TC1720 RS 422 RS 449 Async Sync FIBER OPTIC MODEM with Optiona...

Page 2: ...uipment Location 8 Installation Procedure Summary 8 Typical Point to Point Application Diagram 9 Chapter 3 Troubleshooting 10 General 10 All LEDs are Off 10 Alarm LED 10 Optic Cable Types 10 Calculati...

Page 3: ...449 Async Sync Data Rates Async Up to 10 Mbps Sync Up to 5 Mbps Connector DB37 Male DCE DTE switch selectable Virtual Pin Assignments Theory of Operation Figure 1 Connecting a DTE to DCE Device Logic...

Page 4: ...signal lost RxB Solidly lit optic received OK from secondary side B side Flashing when optic signal lost or B side is not enabled USE B Solidly lit when secondary optic signal is being used due to pr...

Page 5: ...t alarm These functions can be initiated from one of four DIP switches accessible from front panel Under normal operation all the switches should be set in UP position SW1 Internal PCB Dip Switches Th...

Page 6: ...ivity and distance are listed for reference only These numbers may vary RS 422 449 Termination Resistor A termination resistor is usually necessary for RS 422 applications Without proper termination t...

Page 7: ...ill force the switch to a CLOSED position This relay can be used in conjunction with an external device to signal an alarm condition Power Supply and Rear Panel The TC1720 consumes very low power The...

Page 8: ...e all DIP switches are in the up Off position and double check the polarity at the DC power s terminal block connector The installation procedure is as follows 1 Connect your DTE DCE Device to the DB3...

Page 9: ...ntegrity of the system and provide a benchmark for future troubleshooting efforts see Chapter 3 Troubleshooting Figure 5 Typical Point to Point RS 442 449 Application Diagram DTE DEVICE Dual Optic Mod...

Page 10: ...f the link is within the loss budget of the device and 2 it will provide a benchmark for future testing For example a system that has been tested as having 6dB of signal loss when installed should not...

Page 11: ...x A LED on the front panel being solidly lit This indicates that the receiving cable is correctly connected to the remote unit s optic TxA On Dual Optics Models the same applies to RxB and TxB Dual Op...

Page 12: ...nnectors ST or FC Pre Installation Tests 1 Make sure the appropriate power supply accompanies the TC1720 unit see page 7 2 To verify that the unit functions properly plug in only the power connector t...

Page 13: ...Now turn the front panel SW2 2 LOCLB dip switch to the down On position to enable the Local Loopback test function 8 At this point the tester should indicate a Synchronous signal being received indica...

Page 14: ...gh 128Kbps Synchronous 5 The data bits should be selected as 8 bits and the data pattern should be set to 2047 on the BERT tester 6 At this point the tester should indicate a Synchronous signal being...

Page 15: ...nd connectors are good and the cable has been connected properly 7 Verify the following LEDs on both the Local and Remote TC1720 units On the Local unit the TxD RxD TxClk RxClk RxA PWRA or PWRB and Vc...

Page 16: ...een connected properly 6 Verify that the TxD RxD TxClk RxClk RxA PWRA or PWRB and Vcc LEDs are solidly lit on both the Local and Remote TC1720s Note the ALARM LED will be Off since there are optical f...

Page 17: ...ding SW1 1 switch 1 of the SW1 Internal DIP Switch to the right on position 2a For Sync units SW1 4 disabled Off Turn on the RMTLB by pressing down the DIP switches 1 of Front Panel DIP Switches on th...

Page 18: ...Optic RxA DRY CONTACT ALARM SW1 1 2 3 4 5 6 7 8 ON SW1 Internal DIP Switches Used to configure TC1720 to enable the signal generator test to change DCE Off or DTE On device to enable secondary optic...

Page 19: ...er Indicators System status ALARM PWR A PWR B Vcc Rx A Rx B USE B DTE Electrical Signal Status RxD TxD Optic Signal Status TxA RxB for Dual Optics TxB and RxB Power Source Standard 12VDC 500mA typical...

Page 20: ...tion may first inspect such goods at the premises of the Buyer or may give written authorization to Buyer to return the goods to TC Communications Inc transportation charges prepaid for examination by...

Reviews: