TECHNICAL SPECIFICATIONS

Network Video Technologies

(+1) 650.462.8100 • +44 (0) 208 977-6614

nvt.com • [email protected]

Page 24 of 25

E T H E R N E T  ( U p l i n k )  I N T E R F A C E S

SFP Port:                                                                            Gigabit Ethernet

RJ45 Port:                                              10/100/1000 BaseT IEEE 802.3ab

                                              auto-negotiation, auto MDI / MDX crossover

    

Protection:                                                     Industrial transient protection

Wire type:                                                                             Cat5 or better

Distance:                                                                  up to 328 feet (100m)

T B u s   L I N K   I N T E R E R F A C E

Connectivity:                Sixteen ports, each equipped with a BNC and RJ45

Power Source:                               Each port delivers class 2 (SELV) power

                                                    56VDC at up to 1 amp, to power remote

                                                     NVT transmitters and their PoE devices.

    

Wire type:                       Coax, single- or multi-pair UTP, 18/2, or STP wire  

Impedance:                                                                             25 to 100 

Ω

Topology:                      Bus architecture supports star, daisy-chain, or any

combination. One control-room Receiver may

support multiple remote TBus Transmitters.

Data throughput:                                 150 Mbps total network bandwidth*

with dynamic bandwidth allocation

Latency:                                                                                              3 mS

Wire distance:                                   Up to 8,000 feet, 1.5 miles (2.5 Km)*

Transmission technology:                                                            IEEE 1901

Encryption:                                   128-bit AES, through one-button Joining

* I M P O R T A N T   N O T E :  

Data rate, distance, and number of devices may be lower due to wire
voltage-drop, power supply capacity, or signal attenuation. 
See pages 8 & 9.

  

W A R N I N G :  

For safety, never use more than two power supplies within a TBus 
channel. Never use more than one 60 watt remote power supply 
on each TBus channel.

                                                                                    

A L A R M   O U T P U T S

Main: Rear screw terminals 5 & 6 open on fault                   60V 100mA
Auxiliary: Rear screw terminals 7 & 8 open on fault      1,000V isolation

R E G U L A T O R Y

UL Listed to IEC/UL 60950-1
Complies with FCC part 15A limits

W A R R A N T Y

Limited Lifetime

Specifications subject to change without notice.

L E D   S T A T U S   I N D I C A T O R S

M E C H A N I C A L   /   E N V I R O N M E N T A L

Body Dimensions:                                                  17 in (432 mm) wide

                                                                             1.73 in (44 mm) high
                                                                             10 in (254 mm) deep

                                                       excluding connectors and rack ears

Shipping weight:                                                       10.37 lbs (4.70 Kg)

Operating / storage temperature:        -40°F to 185°F (-40°C to +85°C)
                                                                   20 to 85% relative humidity 

                                                                                     non-condensing

Generated heat:                                                                                      
Under full 220W load, hub alone                                       250 BTU/hour

Under full 220W load, including 
remote transceivers & cameras                                     1,100 BTU/hour

Under full 470W load, including 
remote transceivers & cameras                                     2,200 BTU/hour
(470 W load requires auxiliary 
NV-PS56-250W power supply)

Transient immunity:                                         5 x 20µS 3,000A, 6,000V

                                                                                   ESD 20KV, 200pF

P O W E R   S U P P LY

                                                                               

The NV-ER1808i contains a 250 watt 56VDC power supply that operates
off 100 to 240 VAC, 50/60 Hz. Current draw can be up to 4.5 amps. The
NV-ER1808i consumes up to 30 watts, leaving 220 watts for the eight
TBus ports.

Fuse rating:                                                                            250V 5A T

Use only the power cord provided with the unit or equivalent UL approved
type SPT-2, SVT, or SJT 18/3 AWG 100~240 VAC, 1 Amp 60°C max 15 ft
(4.5 m) long. One end with IEC380-C13 appliance coupler and the other
end with NEMA 1015P or equivalent for your country.

An optional external 250 watt power supply may be added for high load
applications, or for redundancy, bringing the total power to 500 watts.
The external power supply connections use an 8-conductor pluggable
Phoenixstyle connector suitable for up to 16AWG (1.3 mm) conductors. 

Only one external 250 watt power supply may be used with each 
NV-ER18016i. For multi-hub environments, up to three power supplies
are available in a shared 1U enclosure:

Single External Power Supply
Model NV-PS56-250W:                                                           56V 250W

Dual External Power Supply
Model NV-PS56-250W-2                                                Dual 56V 250W

Triple External Power Supply                                                                  
Model NV-PS56-250W-3                                               Triple 56V 250W

1

NV-ER1816

2

1

3

1

4

1

5

1

6

1

11

2

3

4

5

6

7

8

9

0

1

Auxiliary

Join

Link

10/100/1000

10/100/1000

Main

Power

16-Port Ethernet Receiver

Remote

device

detected

Internal

Power

Optional
External

Power

Link

Flashes
with Data

Ethernet

Uplink Tx

Flashes
with Data

SFP

Uplink Rx

Flashes
with Data

SFP

Uplink Tx

Flashes
with Data

Ethernet

Uplink Rx

Flashes

when

initializing

or Joining

Green

when>0.5W

Per-channel

Load

Summary of Contents for NV-ER1816i

Page 1: ...o not install the unit in an environment where the operating ambient temperature exceeds 185 F 85 C The ventila tion should not be impeded by covering the unit with items such as newspapers table clot...

Page 2: ...6 VDC power supply can be optionally augmented by an external 250 watt auxiliary power supply supporting redundancy and or higher power applications The NV ER1816i is backed by NVT s award winning cus...

Page 3: ...Power LEDs on both Transceivers will return to a steady on condition and their green TBus Link LEDs will illuminate indicating a successful Join One TBus Link LED will remain on solid The other may wi...

Page 4: ...deration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring Appropriate con...

Page 5: ...plied mounting brackets to the TBus Hub chassis using the supplied screws Note that the brackets allow the Hub to be mounted with either the front or rear facing out Connect the TBus wiring from as ma...

Page 6: ...ans that multiple remote camera end transmitters may be connected together to one receiver at the control room Wire may be star topology daisy chained or any combination TBus supports virtually any ty...

Page 7: ...rt that is sent in the direction of the camera That Report is monitored and passed on by switches and routers within the network That monitoring is called IGMP Snooping These switches and routers each...

Page 8: ...we have up to 13V of allowable voltage drop on the wire The voltage will dip in proportion to the remote camera load The graph below shows what PoE power distances are supported for various loads and...

Page 9: ...com Network Video Technologies 1 650 462 8100 44 0 208 977 6614 nvt com info nvt com 1 000 ft 700 ft 500 ft 10 000 ft 7 000 ft 5 000 ft 3 000 ft 2 000 ft 100 ft 300 ft 200 ft 20 000 ft 1 000 m 700 m 5...

Page 10: ...y wire any wire IP Camera NV ET1801 Cat5 IP Camera NV ET1801 Cat5 IP Camera NV ET1801 Cat5 IP Camera NV ET1801 Figure 5 Sixteen Cameras Star Topology 328ft 100m Cat5 SFP Port Hybrid DVR or NVR LAN WAN...

Page 11: ...t 100m IP Cameras Eight NV ET1804s Eight NV ET1801s NV ER1816i NV PS56 250W 250W Auxiliary Power Supply 328ft 100m Cat5 Hybrid DVR or NVR LAN WAN Switch or Router SFP Port Network Video Technologies 1...

Page 12: ...re 9 Mixed Media 328ft 100m Cat5 328ft 100m Cat5 Hybrid DVR or NVR LAN WAN Switch or Router UTP wire Coax Coax IP Camera NV ET1801 NV ER1816i NV ER1816i NV ER1816i 328ft 100m Cat5 Hybrid DVR or NVR LA...

Page 13: ...ing Cat5 328ft 100m RJ45 Cat5 Hybrid DVR or NVR LAN WAN Switch or Router Laptop for diagnostics any wire IP Camera NV ET1801 NV ER1816i Cat5 328ft 100m RJ45 any wire IP Camera NV ET1801 NV ER1816i Fig...

Page 14: ...rs Each power supply within a multi output unit is intended to support one and only one TBus Hub WARNING For safety never use more than one Auxiliary Power Supply with each NV ER1816i Receiver Hub DUA...

Page 15: ...Open your web browser and point it to https 192 168 254 1 which is the factory default address of the NV ER1816i Hub For best results please use the latest version of Internet Explorer with the latest...

Page 16: ...Submit The NV ER1816i supports one username and password 1 NV ER1816 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 Auxiliary Join Link 10 100 1000 10 100 1000 Main Power 16 Port Ethernet Receiver JoinButton F...

Page 17: ...on a naming description field is available The hub will remember each entered description associated with every transmitter MAC address This memory is non volatile TBus devices must be Joined to commu...

Page 18: ...re 22 Power Page Network Video Technologies Security Industry Leader TBus Sixteen Port Ethernet Receiver Model NV ER1816i HW Rev A FW rev 1 2 IP Address 192 168 254 0 Channel 1 Watts 0 50 45 40 35 30...

Page 19: ...iver Network Video Technologies Security Industry Leader TBus Sixteen Port Ethernet Receiver Model NV ER1816i HW Rev A FW rev 1 2 IP Address 192 168 254 1 Figure 23 Monitor Page Rear Parking Lot Camer...

Page 20: ...lick Restore Firmware Upgrade Firmware upgrades will be available from time to time on the nvt com website For security most CCTV LANs are closed not accessible to the internet To avoid this issue fir...

Page 21: ...unable to perform this Switch configuration then NVT recommends you instead manually configure the NV ER1816i to generate an IGMP Report for each multicast camera See below If your network has no IGMP...

Page 22: ...Transmitter Netw ork Video Technologies Link Data 1 PoE Data 4 PoE Data 3 PoE Data 2 PoE 50W PoE n o Eth er ne t no an alog Quality 10 100 PoE 56VDC JOIN LINK NV ET1804 Ethernet Transmitter Netw ork...

Page 23: ...NV PS56 60W 56V DC power supply 60 watts with IEC line cord NV PS56 90W 56V DC power supply 90 watts with IEC line cord Do not use with NV ER1816i NV BNCT BNC T adaptor NV EC4BNC 1 4 BNC splitter ada...

Page 24: ...ng connectors and rack ears Shipping weight 10 37 lbs 4 70 Kg Operating storage temperature 40 F to 185 F 40 C to 85 C 20 to 85 relative humidity non condensing Generated heat Under full 220W load hub...

Page 25: ...obligation on the part of NVT with respect to any of the products In the event that any of the products is dam aged altered or modified without the express written consent of NVT any warranty for tho...

Reviews: