background image

• 100 BaseT transmision; Network speeds up to 150 Mbps*; Up to 8,000ft (2,500m)*

• Powers PoE, PoE+, or High Power PoE cameras (or other PoE devices), up to 50 watts*

• Dual 1000BaseT uplink ports (RJ45 & SFP)

• Use with NV-ET1801 or NV-ET1804 TBus Transmitters

• One TBus port at the network-end can support multiple remote Transmitters/IP cam-

eras

• 56 VDC is distributed over the TBus to all connected equipment

• Easy configuration, no PC required; Browser based moitoring & control available

• Transparently supports all networking protocols (UDP, TCP/IP, HTTP, Multicast*, etc.)

• 128-bit AES encrypted transmission; Built-in transient protection

The  NVT  Model  NV-ER1816i  TBus  Sixteen  Port  PoE+  Receiver  Hub  is  a  1U  19”  rack-
mountable bus-architected ethernet switch, that together with remote TBus transmitters, is
capable of supporting up to 64 10/100 BaseT Ethernet and PoE+ powered devices.

The  TBus  transmission  medium  can  be  coax,  2-wire/UTP,  or  Shielded  Twisted-Pair.  Data
rates up to 150 Mbps are achievable, making these devices the ideal choice in new or legacy
installations where existing cable is re-deployed as part of an upgrade to IP cameras.

An internal 250 watt 56 VDC power supply can be optionally augmented by an external 250
watt auxiliary power supply, supporting redundancy and/or higher power applications.

The NV-ER1816i is backed by NVT’s award winning customer suooprt, limited lifetime war-
ranty, and advance replacement. No IP or MAC addressing configuration is required, yet is
available for browser-based monitoring and control. This provides exceptional yet simple
configuration  and  diagnostics  for  the  installer  or  remote  monitoring  facility.  Status  LEDs
indicate power, Ethernet/PoE, and TBus connectivity/activity.

*  Distance  and  number  of  devices  supported  may  be  lower  due  to  power  supply  capacity  and  wire  voltage-drop.  See  Wire  Distance
Charts on page 8. Aggregate TBus bandwidth is dynamically allocated (shared based on traffic), and decreases with wire distance. See
Wire Distance Chart on page 9. Multicast requires an IGMP Querier, either in a network switch, or in the NV-ER1816i Receiver Hub. High

Page 2 of 25

PRODUCT OVERVIEW

Network Video Technologies

(+1) 650.462.8100 • +44 (0) 208 977-6614

nvt.com • [email protected]

Sixteen Port PoE+ Receiver Hub

Model NV-ER1816i

1

NV-ER1816

2

1

3

1

4

1

5

1

6

1

11

2

3

4

5

6

7

8

9

0

1

Auxiliary

Join

Link

10/100/1000

10/100/1000

Main

Power

16-Port Ethernet Receiver

USE ONL

WITH A 250V FUSE

(no an

alog

 / no ether

net)

OUTPUTS:  56VDC       1AMP MAX. PER PORT,  4.5A MAX, TOTAL

Summary of Contents for NV-ER1816i

Page 1: ...o not install the unit in an environment where the operating ambient temperature exceeds 185 F 85 C The ventila tion should not be impeded by covering the unit with items such as newspapers table clot...

Page 2: ...6 VDC power supply can be optionally augmented by an external 250 watt auxiliary power supply supporting redundancy and or higher power applications The NV ER1816i is backed by NVT s award winning cus...

Page 3: ...Power LEDs on both Transceivers will return to a steady on condition and their green TBus Link LEDs will illuminate indicating a successful Join One TBus Link LED will remain on solid The other may wi...

Page 4: ...deration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring Appropriate con...

Page 5: ...plied mounting brackets to the TBus Hub chassis using the supplied screws Note that the brackets allow the Hub to be mounted with either the front or rear facing out Connect the TBus wiring from as ma...

Page 6: ...ans that multiple remote camera end transmitters may be connected together to one receiver at the control room Wire may be star topology daisy chained or any combination TBus supports virtually any ty...

Page 7: ...rt that is sent in the direction of the camera That Report is monitored and passed on by switches and routers within the network That monitoring is called IGMP Snooping These switches and routers each...

Page 8: ...we have up to 13V of allowable voltage drop on the wire The voltage will dip in proportion to the remote camera load The graph below shows what PoE power distances are supported for various loads and...

Page 9: ...com Network Video Technologies 1 650 462 8100 44 0 208 977 6614 nvt com info nvt com 1 000 ft 700 ft 500 ft 10 000 ft 7 000 ft 5 000 ft 3 000 ft 2 000 ft 100 ft 300 ft 200 ft 20 000 ft 1 000 m 700 m 5...

Page 10: ...y wire any wire IP Camera NV ET1801 Cat5 IP Camera NV ET1801 Cat5 IP Camera NV ET1801 Cat5 IP Camera NV ET1801 Figure 5 Sixteen Cameras Star Topology 328ft 100m Cat5 SFP Port Hybrid DVR or NVR LAN WAN...

Page 11: ...t 100m IP Cameras Eight NV ET1804s Eight NV ET1801s NV ER1816i NV PS56 250W 250W Auxiliary Power Supply 328ft 100m Cat5 Hybrid DVR or NVR LAN WAN Switch or Router SFP Port Network Video Technologies 1...

Page 12: ...re 9 Mixed Media 328ft 100m Cat5 328ft 100m Cat5 Hybrid DVR or NVR LAN WAN Switch or Router UTP wire Coax Coax IP Camera NV ET1801 NV ER1816i NV ER1816i NV ER1816i 328ft 100m Cat5 Hybrid DVR or NVR LA...

Page 13: ...ing Cat5 328ft 100m RJ45 Cat5 Hybrid DVR or NVR LAN WAN Switch or Router Laptop for diagnostics any wire IP Camera NV ET1801 NV ER1816i Cat5 328ft 100m RJ45 any wire IP Camera NV ET1801 NV ER1816i Fig...

Page 14: ...rs Each power supply within a multi output unit is intended to support one and only one TBus Hub WARNING For safety never use more than one Auxiliary Power Supply with each NV ER1816i Receiver Hub DUA...

Page 15: ...Open your web browser and point it to https 192 168 254 1 which is the factory default address of the NV ER1816i Hub For best results please use the latest version of Internet Explorer with the latest...

Page 16: ...Submit The NV ER1816i supports one username and password 1 NV ER1816 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 Auxiliary Join Link 10 100 1000 10 100 1000 Main Power 16 Port Ethernet Receiver JoinButton F...

Page 17: ...on a naming description field is available The hub will remember each entered description associated with every transmitter MAC address This memory is non volatile TBus devices must be Joined to commu...

Page 18: ...re 22 Power Page Network Video Technologies Security Industry Leader TBus Sixteen Port Ethernet Receiver Model NV ER1816i HW Rev A FW rev 1 2 IP Address 192 168 254 0 Channel 1 Watts 0 50 45 40 35 30...

Page 19: ...iver Network Video Technologies Security Industry Leader TBus Sixteen Port Ethernet Receiver Model NV ER1816i HW Rev A FW rev 1 2 IP Address 192 168 254 1 Figure 23 Monitor Page Rear Parking Lot Camer...

Page 20: ...lick Restore Firmware Upgrade Firmware upgrades will be available from time to time on the nvt com website For security most CCTV LANs are closed not accessible to the internet To avoid this issue fir...

Page 21: ...unable to perform this Switch configuration then NVT recommends you instead manually configure the NV ER1816i to generate an IGMP Report for each multicast camera See below If your network has no IGMP...

Page 22: ...Transmitter Netw ork Video Technologies Link Data 1 PoE Data 4 PoE Data 3 PoE Data 2 PoE 50W PoE n o Eth er ne t no an alog Quality 10 100 PoE 56VDC JOIN LINK NV ET1804 Ethernet Transmitter Netw ork...

Page 23: ...NV PS56 60W 56V DC power supply 60 watts with IEC line cord NV PS56 90W 56V DC power supply 90 watts with IEC line cord Do not use with NV ER1816i NV BNCT BNC T adaptor NV EC4BNC 1 4 BNC splitter ada...

Page 24: ...ng connectors and rack ears Shipping weight 10 37 lbs 4 70 Kg Operating storage temperature 40 F to 185 F 40 C to 85 C 20 to 85 relative humidity non condensing Generated heat Under full 220W load hub...

Page 25: ...obligation on the part of NVT with respect to any of the products In the event that any of the products is dam aged altered or modified without the express written consent of NVT any warranty for tho...