TBS Solvent Recovery Systems have been designed and manufactured to be ignition resistant if operated in 

a highly volatile environment (explosion proof).   All units are shipped with a normal 15 amp Hospital 

Grade, ETL™ & UL approved electrical plug. Be advised that if you intend to operated your unit in a 

dangerously volatile environment an explosion proof plug must be installed with its special receptacle. 

 

Solvent Containment

 - TBS offers a stainless steel splash pan, designed for your equipment, to be placed 

on the floor under your recovery unit.   This pan is recommended for use as a safety pan to prevent solvents 

from spilling onto the floors in case of an over flow due to operator error. 

 

Appropriate 3-gal containers for the collection of recycled solvents and run off waste are available from 

TBS. 

 

Safe Exposure Temperature

 - The temperature should be at 50°C or below, according to the top bulb 

thermometer, before the distilling chamber cover is opened.   Opening the cover at a higher temperature will 

release solvent fumes into the surrounding air and can also cause burn injury to the operator.   

 

NOTE:  Opening the cover sooner than one hour after the distillation cycle has finished wil cause the cover   

              gasket to swell. 

 

Summary of Contents for SR12

Page 1: ...Triangle Biomedical Sciences Inc Solvent Recovery System Operation And Service Manual SR12 Version 1 2 Serial ___________________...

Page 2: ...ION 4 Application 4 Function 4 Separation Module 4 Safety Measurers 4 OPERATIONAL SAFETY 4 Location 4 Solvent Containment 4 Safe Exposure Temperature 5 OPERATING PROCEDURES 6 Purpose 6 Procedure for A...

Page 3: ...Page 3 GLOSSARY 15...

Page 4: ...ansfer the benefit of such warranties to the user This warranty supersedes and is given in lieu of all implied warranties and is void if user does not provide unit with continuous ample electrical pow...

Page 5: ...illation using the Separation Module and Baffle The Switching Module allows an operator to set a fraction temperature at which the distillate of the different solvents will be separated The fraction t...

Page 6: ...on the floor under your recovery unit This pan is recommended for use as a safety pan to prevent solvents from spilling onto the floors in case of an over flow due to operator error Appropriate 3 gal...

Page 7: ...taminated solvent in the distilling chamber up to 3 gallons NOTE Take special care NOT to allow any contaminated solvent to enter the Vapor Collector Duct Manifold when you are filling the distilling...

Page 8: ...hen operating This could create a dangerous situation Xylene 1 Place clean and dry collection containers under each of the lower distillate solvent outlet nozzles left and right 2 Verify that the Ther...

Page 9: ...overy cycle has been completed let the unit cool to at least 50 C prior to opening the secured top Premature opening will allow a release of solvent fumes into the surrounding atmosphere and can also...

Page 10: ...156 377 Cyclohexane 81 260 Cyclohexanon 155 419 1 2 DiChlorethane 84 412 DiEthyl Cellosolve 121 208 DiEthyl Ketone 104 445 Ethanol 82 400 Ethyl Acetate 79 427 Ethyl Amyl Keytone EAK 160 Ethylene Glyc...

Page 11: ...113 46 80 Carbon Tetrachloride Tetrachloromethane 78 110 1 1 2 2 Tetrachloroethane Acetylene Tetrachloride 147 160 Tetrachloroethylene Pestabil Vors Perchloroethylene Per 121 150 Trichloroethane 1 1...

Page 12: ...o control the temperature of the thermal oil that transfers heat to the distilling chamber Range 40 200 C Note The oil temperature is generally 15 20 C higher than the temperature of the contaminated...

Page 13: ...time lasts much longer than 4 hours 1 Contaminated solvent contains too much water 2 Thermal oil level is low 3 Thermal oil is old and dirty 4 Heating elements need cleaning 1 Replace the solvent 2 Ad...

Page 14: ...er 11 Cooling Fan Motor Expl Proof 12 3 Way Fraction Switch Expl Prf 13 Heater Cable Sheath Pipe Expl Prf 14 Solvent Receiver Tanks 15 Solvent 16 Oil Discharge 17 Thermal Oil Level Indicator 18 Workin...

Page 15: ...g Thermostat T1 384010 Safety Thermostat T2 465000 White Warning Light 465001 Red Warning Light 465002 Green Warning Light 475000 Ventilator Motor 468402 Heating Element 385007 Timer 425002 Control Kn...

Page 16: ...since the distlland mixture is forced into the area in which only pure material is desired Fraction A portion of the collected separated material recovered from the head of the still Fractional Disti...

Reviews: