7 Troubleshooting
dominant; switch the system via remote control to “Run”
4
System running, yellow warning
flashing, filter saturation indicator lit
(green+yellow)
Filter is partially saturated (depending on the system type,
the filter in question is displayed yellow additionally)
Green range – filter saturation OK
Yellow range – order replacement filter
Red range – filter completely saturated - replace
5
Speed cannot be changed on the
system
Remote control connected, external speed control (Pin
14,15)
Note: Interface is partly only available as an option.
External speed control is dominant over the manually set speed on
the device
6
Speed cannot be changed via the
interface
Speed setting on the system dominant
Note: Interface is partly only available as an option.
External speed control is dominant over the manually set speed on
the device
7
No/low extraction level, filter saturation
indicator does not indicate filter
replacement
Intake line blocked, defective, bent or not connected
Clean or replace intake line
Extraction level not correctly set
Increase extraction level at the speed dial (front) or via remote
control
Motor/control defective
Contact regional representative office
8
System not running or vibrating heavily Motor bearing defective
Replace motor or contact regional representative office
Contamination on impeller of the motor
Check filter for leaks or contact regional representative office, if
necessary
Pos. 1: Run/Standby button
Pos.
5:
Filter status indicator
Pos. 2: Button for manual activation of filter
cleaning (only on systems with filter
cartridges)
Green: Filter OK
Yellow
:
Check filter status indicators (Pos. 6) –
place order for filter, if necessary
Red:
Max. filter saturation reached – system
switches off - check filter status
indicator (Pos. 6)
Pos. 3: Extraction level control
Pos.
6:
Status message for filter cleaning (only
on systems with filter cartridges)
Pos. 4: Filter saturation indicator (shows the
filter saturation for all filter installed in
the system together)
Pos.
7:
Display, motor/turbine fault message
Pos.
8:
Display, power setting / operating hour
meter
Pos.
9:
System fault indicator
FP 130/150 only
10
System does not clean
Filter differential pressure not yet reached
In the differential pressure monitoring mode, the system is in the
green range or at the beginning of the yellow range, everything is
OK
No compressed air at the line or compressed air line not
connected
Check pressure or connect compressed air line:
1.5 - 2 bar
Cleaning module not connected
Connect the cable for cleaning to the socket under the interface
Cleaning module is defective
Check the cable and solenoid valve for damage, or contact the
regional representative office
Incorrect cleaning settings
The customer can set individual configurations via the interface; if
changes have been made here, check the settings for plausibility
11
System cleans continuously at short
intervals
Filter cartridges heavily contaminated / service life exceeded
The system tries to reduce the differential pressure of the filter
cartridge using several cleaning cycles; when this fails, it means
that the filter is completely saturated and must be replaced
12
System cleans at very short intervals
and then switches off
Filter service life exceeded / filter completely saturated / can
no longer be cleaned
If a set number of cleaning attempts is exceeded, the filter is
completely saturated
→ replace the filter cartridges!
13
Dust escapes from the filter housing
Dust collector is not inserted
Open service door and insert dust collector
Dust collector leaking
Open service door and check seals; is the dust collector properly
tensioned?
FPV200-202 only
14
System does not clean
System is not switched on
Switch the system on at the power switch
No compressed air at the line or compressed air line not
connected
Check pressure or connect compressed air line
max. 4 bar
82-236
1
2
4
3
5
6
7
8
9
5
5
Summary of Contents for LN Series
Page 2: ...Sprachen Languages Deutsch 3 English 50 Fran aise 97 Espanol 143 Italiano 189 2 236...
Page 48: ...9 Schaltplan 48 236...
Page 49: ...10 Konformit tserkl rung Declaration of conformity 49 236...
Page 95: ...9 Circuit diagram 95 236...
Page 96: ...10 Konformit tserkl rung Declaration of conformity 96 236...
Page 141: ...9 Plan de c blage 141 236...
Page 142: ...10 Konformit tserkl rung Declaration of conformity 142 236...
Page 187: ...9 Esquema de conexiones 187 236...
Page 188: ...10 Konformit tserkl rung Declaration of conformity 188 236...
Page 221: ...7 Ricerca e eliminazione delle anomalie max 4 bar 221 236...
Page 234: ...9 Schema elettrico 234 236...
Page 235: ...10 Konformit tserkl rung Declaration of conformity 235 236...