Apollo Maxx User Manual
27
6.1.2 MPPT Fault
Fault Code
Description
Solution
17
The DC bus is over voltage
Check the PV input voltage.
18
The battery is under voltage
Check the battery voltage.
19
Hardware protection against DC bus over
voltage
Check the battery voltage and the
charger output voltage
20
Buck short circuit
Check if there is a short circuit at
the MPPT output.
21
The Buck 1 is over current
Check
the
MPPT
output
connection. Restart the equipment,
contact the installer in case the
error still exists.
22
The Buck 2 is over current
23
The control board's temperature is too
high
Check fan ventilation.
24
The heat sink's temperature is too high
Too high ambient temperature.
25
Abnormal auxiliary power supply
Restart the MPPT. Contact the
installer in case the error still exists.
26
Abnormal auxiliary power supply
(hardware)
27
Abnormal sampling
28
Abnormal ROM
6.2 Warning code
When inverter fault occurs, press the ESC button to view the warning code. The digital tube in the
middle of the LCD will display the warning code.
6.2.1 Inverter Warning
Warning Code
Description
Solution
01
The battery is over voltage
Check the battery voltage.
02
The battery is under voltage
Check the battery voltage.
03
The battery is under voltage
protection
Check the battery voltage.
04
Overload warning
Reduce the loads.
05
Heat sink NTC fail
Power off the inverter and check the
Summary of Contents for APOLLO MAXX Series
Page 1: ......