5.3 LCD Setting
After press and holding the <ENTER> button for 3 seconds, the inverter will enter the setting
mode. Press <UP> or <DOWN> button to select setting programs. Then press the <ENTER>
button to confirm the selection of the setting programs, or press the <ESC> button to exit the
setting mode.
After confirm the selection of the setting programs, press the <UP> and <DOWN> button to
modify the parameters. Press the <ENTER> button to confirm the modification, or press the
<ESC> button to cancel.
The digital tube on the left side of LCD displays [PA] standing for PASS when the parameters are
set successfully, otherwise it will display [FA] standing for FAIL.
Setting item
Item
Description
Setting Range
/
Inverter Parameter
00
Output voltage
220~240V(@230V)
110~120V(@120V)
Step:10V
Default:
230V(@230V)
120V(@120V)
01
Output frequency
50~60Hz
Step:10Hz
Default:
50Hz(@230V)
60Hz(@120V)
(only in standby mode)
05
Fault unlock
1 (Press <ENTER> to trigger
the effect once)
Default:0
06
Fan dedusting
1 (Press <ENTER> to trigger
the effect once)
Default:0
ACin Parameter
11
Power assist current
0~Max(Rate AC input Current)
Step:1A
Default: Max
Summary of Contents for RiiO Sun Series