Energy Hub User Manual
19
9
Discharge low
temperature
protection
➢
Please check if the ambient temperature at the Energy
Hub installation location is below -20°C. If so, please
connect the ALTERNATOR to raise the temperature of the
lithium battery inside the Energy Hub by heating the
heating film inside the Energy Hub.
➢
If this still does not solve the problem, please contact your
dealer.
10
Charging high
temperature
protection
➢
Please check that the ambient temperature at the Energy
Hub installation location is not too high.
➢
Check that the charging current of the external charger
matches that of the Energy Hub.
➢
If this is correct, please contact your dealer.
11
BMS circuit high
temperature
protection
➢
Check that the ambient temperature at the Energy Hub
installation location is not too high.
➢
Please check that the discharge current and discharge
time of the Energy Hub do not exceed the specified
requirements (see 9.Specification).
➢
If the above is correct, please contact your dealer.
12
Low
temperature
protection for
BMS circuits
➢
Please check that the ambient temperature at the location
where the Energy Hub is to be installed is below -40°C. If
so, the Energy Hub is not suitable for operation at such a
low ambient temperature and the best ambient
temperature for the Energy Hub installation is above
-20°C.
➢
If the above is normal, please contact your dealer.
13
External input
overvoltage
protection
➢
Check that the charging voltage of the external charger
matches that of the Energy Hub, which should be
14.0~14.2V.
➢
Check if there is any abnormality in the external charger.
➢
If all of the above are normal, please contact your dealer
after switching off the charger.
14
BMS internal
faults
➢
Please contact your dealer.