![Taylor R280 Operator'S Manual Download Page 24](http://html2.mh-extra.com/html/taylor/r280/r280_operators-manual_3763138024.webp)
20
Model R280
•
Use the Up
and Down
arrow buttons to find the desired function.
•
Press the Enter
button to select the desired function.
•
Basket
Size
buttons
also
function
as
numbers:
(Left Small=1, Left Medium=2, Left Large=3, Right Small=4, Right Medium=5, Right Large=6)
Note:
If a password has been set, there is a Service Password available to access both the Manager Menu and
Diagnostic Menu. The Service Password is 22463†.
d13
Bypass Refrigeration
Note:
Volatile setting.
Allows the refrigeration system to be disabled.
Display will read the current status of the refrigeration system (
rF on
or
rF OFF
).
Up arrow enables the refrigeration system. Down arrow disables
the refrigeration system.
Enter button saves the setting, exits the function, returns to d01.
Note:
The refrigeration circuit contains anti-short-cycle protection.
The refrigeration compressor cannot be restarted until the 2-minute
short cycle delay is met.
d14
Display Scale Weight
Displays the current calibrated weight on the scale. Display will read
“
[SCL]
” with alternating flashing brackets.
Use Size buttons to select the side to be displayed. Enter button
exits function and returns to d01.
d15
Display Scale Volts
Displays the current uncalibrated input from the scale. Display will
read “
[SCL]
” with alternating flashing brackets.
Use Size buttons to select the side to be displayed. Enter button
exits function and returns to d01.
d16
Exercise Mode
Note:
Volatile setting.
Caution:
Ensure the hopper is
empty before using Exercise mode.
Exercise mode is designed to “break in” a replaced component. When
the Dispenser is in exercise mode, the selected side(s) will
continuously cycle.
Display will read “
[-E-]
” with alternating flashing brackets. Use Size
buttons to select the side to be exercised. Up arrow selects exercise
mode:
Display reads “
[ on
” (“ on]”). Down arrow clears exercise mode.
Display reads “
[ OFF
” (“ OFF]”).
Enter button executes selection and exits to d01.
d17
Restore Defaults
Restores all settings to factory defaults. Display defaults to “
rd. no.
”
Up arrow will select restore defaults:
display reads “
rd.YES.
”
Down arrow will deselect restore defaults:
display will read “
rd. no.
”
Enter button will execute selection and exit to d01.
Caution:
This function will erase scale calibrations, temperature
probe calibrations, changes to target weights, temperature set point,
alarm set point, and will reset passwords to defaults.
d18
Power Volts
Displays the current power supply voltage.
Enter button exits the function and returns to d01.
Diagnostic
Functions
Function Name
Description
3
4
5
6