14
CONFIGURATION (CONFIG) FUNCTIONS MENU STRUCTURE
•
Press the Menu button to find the desired menu then press the OK button to select the menu.
•
Use the Up
and Down
arrow buttons to find the desired function.
•
Press the OK button to select the desired function.
•
Menu button exits function at any time and returns to main menu.
Note:
A Service Password is available. Use the Service Password if the manager’s password has been misplaced.
The Service Password operates in the Service Menu only and will erase the manager’s password and restore to default
(no password). The Service Password sequence is:
Small Basket, Up arrow, Down arrow, Large Basket, Medium Basket (twice), then OK button.
Function Name
Description
Set Targets
Allows the basket load targets to be customized for each basket load size. 0.25 lb. to 2.0 lb.
(100 g to 1,000 g)
Display shows a flashing Small and the current small basket size weight target.
1. Up and Down arrows move through the three basket load sizes (Small, Medium, and
Large). OK button selects basket load size to change.
2. Display shows current basket size target weight flashing. Use the Up and Down arrows
to change the target weight, 0.25 lb. to 2.0 lb. (100 g to 1,000 g). OK button saves the
new target weight and returns to the basket load size selections (Small, Medium, and
Large).
3. Menu button returns to the Configuration menu.
Set Temp
Allows the refrigeration cycle turn ON and turn OFF target temperatures to be changed. The
default is ON at 5°F (-15°C) and OFF at 0°F (-18°C).
•
OK button selects the target (ON or OFF) to be set. The target temperature will be
blinking.
Turn ON target is changed using the Up and Down arrows. The differential between the turn
ON and turn OFF settings remains the same.
Turn OFF target is changed using the Up and Down arrows and can be set independent of
the turn ON target.
•
Up button will increase the target temperature in 1° increments.
•
Down button will decrease the target temperature in 1° increments.
•
OK button changes the selection between ON or OFF.
Menu button saves setting and returns to the Configuration menu
Set Language
Allows the display language to be changed.
•
Use Up and Down arrows to change display language.
OK button stores the new setting and exits to Configuration Menu.
Set Metric
Changes from English to metric units. Display will default to currently selected unit.
•
Up and Down arrows switch between United States and metric.
•
OK button stores the new setting, closes the function, and exits to
•
Configuration menu.
Note:
Scales must be calibrated. (See “Calibrations and Adjustments” on page 1-28.)
Press
the Menu button at any time to abort function and return to the Configuration menu.
Summary of Contents for McDonald's R200
Page 50: ...48 ELECTRICAL DIAGRAM Figure 33 ...
Page 56: ...089363 MCD ...