TO THE INSTALLER
1-3
Models 8752, 8756, and 8757
To the Installer
1
WARNING!
Avoid injury.
•
DO NOT
operate the machine unless it is
properly grounded.
•
DO NOT
operate the machine with fuses larger
than specified on the machine's data label.
•
All repairs should be performed by an
authorized Taylor service technician.
•
The main power supplies to the machine must
be disconnected prior to performing installation,
repairs, or maintenance.
•
For Cord-Connected Machines:
Only Taylor
service technicians or licensed electricians may
install a plug or replacement cord on the
machine.
•
Machines that are permanently connected to
fixed wiring and for which leakage currents may
exceed 10 mA, particularly when disconnected
or not used for long periods, or during initial
installation, shall have protective devices to
protect against the leakage of current, such as a
GFI, installed by the authorized personnel to
local codes.
•
Stationary machines that are not equipped with
a power cord and a plug or another device to
disconnect the appliance from the power source
must have an all-pole disconnecting device with
a contact gap of at least 0.125 in. (3 mm) in the
external installation.
•
Supply cords used with this machine shall be
oil-resistant, sheathed flexible cable not lighter
than ordinary polychloroprene or other
equivalent synthetic elastomer-sheathed cord
(code designation 60245 IEC 57) installed with
the proper cord anchorage to relieve conductors
from strain, including twisting, at the terminals
and protect the insulation of the conductors from
abrasion.
•
If the supply cord is damaged, it must be
replaced by the manufacturer, service agent, or
a similarly qualified person to avoid a hazard.
•
Secure supply cord ground lead to machine in a
location where if the cord is pulled the main
power leads become taut before the ground
lead can break loose.
Failure to follow these instructions may result in
electrocution. Contact your local authorized Taylor
distributor for service.
Beater Rotation
NOTICE!
Beater rotation must be clockwise as
viewed looking into the freezing cylinder.
Electrical connections are made directly to the terminal
block provided in the splice box which is mounted on the
base pan on the right side of the freezer for Model 8752
and located in the splice boxes which are mounted
mid-level on the frame channel on the right and left sides
for Models 8756 and 8757.
Refrigerant
CAUTION!
This equipment contains fluorinated
greenhouse gases (F-Gas) to provide refrigeration using
a hermetically sealed circuit or within foam insulation.
This unit's type of gas, quantity, Global Warming
Potential (GWP) and CO2 tonnes equivalent information
is recorded on the unit's data-label. The refrigerant used
is generally considered non-toxic and non-flammable.
However any gas under pressure is potentially
hazardous and must be handled with caution.
NEVER fill any refrigerant cylinder completely with liquid.
Filling a cylinder to approximately 80% will allow for
normal expansion.
CAUTION!
Use only approved refrigerant
listed on the machine's data label or authorized through a
manufacturer's technical bulletin. The use of any other
refrigerant may expose users and operators to
unexpected safety hazards..
WARNING!
Refrigerant liquid sprayed onto the
skin may cause serious damage to tissue. Keep eyes
and skin protected. If refrigerant burns should occur,
flush immediately with cold water. If burns are severe,
apply ice packs and contact a physician immediately.
!
Summary of Contents for Horizon 8752
Page 14: ...3 4 SAFETY Models 8752 8756 and 8757 Safety 3 Notes...
Page 28: ...5 4 USER INTERFACE Models 8752 8756 and 8757 User Interface 5 Notes...
Page 52: ...9 2 PARTS REPLACEMENT SCHEDULE Models 8752 8756 and 8757 Parts Replacement Schedule 9 Notes...
Page 58: ...11 4 LIMITED WARRANTY ON PARTS 8752 8756 and 8757 Limited Warranty on Parts 11 Notes...