29
Models 336, 338 & 339
Troubleshooting Guide
PROBLEM
PROBABLE CAUSE
REMEDY
PAGE
REF.
10. No freezer operation after
pressing the “AUTO”
button.
a. Unit is unplugged.
a. Plug into wall receptacle.
------
b. The circuit breaker is off
or the fuse is blown.
b. Turn the breaker on, or
replace the fuse.
------
c. The beater motor is out on
reset.
c. Reset the freezer.
14
d. The unit has gone off on
high pressure cut--out.
d. Allow the unit to cool and
reset. Check for dirty
condenser (air cooled) or
loss of water (water
cooled).
25/ 26
11. Product is not feeding into
the freezing cylinder.
a. Inadequate level of mix in
the mix hopper.
a. Fill the mix hopper with
mix.
22
b. The mix inlet hole is
frozen up.
b. The mix hopper
temperature needs
adjustment. Call service
technician.
------
c. The air tube is installed
incorrectly.
c. Install the air tube in the
mix inlet hole, using the
end with the small hole in
the side.
21
d. The air orifice is not
installed.
d. Install the air orifice in the
air tube.
21