OPERATING PROCEDURES
6-5
Model 490
Operating Procedures
6
4.
While the solution is flowing into the freezing cylinder,
brush clean the hopper.
Figure 6-18
When cleaning the mix hopper, take particular care in
brushing the mix-level sensing probes, the mix inlet
hole and the air tube.
Figure 6-19
5.
When sanitizing solution starts leaking from the
prime port, close the prime plug.
6. Place the control switch in the WASH position. This
will cause the sanitizing solution in the freezing
cylinder to agitate. Allow the solution to agitate for
5 minutes.
Figure 6-20
7. Place an empty pail beneath the door spout and raise
the draw arm. Draw off all the sanitizing solution.
When the sanitizer stops flowing from the door spout,
lower the draw arm and place the control switch in
the OFF position.
Important! The machine must not be placed in Auto
mode until all sanitizing solution has been removed
from the freezing cylinder and proper priming
procedures have been completed. Failure to follow
this instruction may result in damage to the freezing
cylinder.
Note: You have just sanitized the freezer.Therefore,
make sure your hands are sanitized before
performing the following step.
8. Stand the air tube in the corner of the mix hopper.
Figure 6-21
12255
12251
13673
12252
Summary of Contents for 490
Page 16: ...4 4 OPERATOR PARTS IDENTIFICATION Model 490 Operator Parts Identification 4 Notes...
Page 18: ...5 2 USER INTERFACE Model 490 User Interface 5 Notes...
Page 32: ...9 2 PARTS REPLACEMENT SCHEDULE Model 490 Parts Replacement Schedule 9 Notes...
Page 38: ...11 4 LIMITED WARRANTY ON PARTS Model 490 Limited Warranty on Parts 11 Notes...