PLEASE NOTE

 

 

 

Tanks should not be lifted over houses, sheds or other property of value, 

nor should they be lifted under low power lines

 

 

 

Tank sites that are cut out of sloping hills will require enough flat area for 

the truck to be unloaded

 

 

 

Unloading on awkward and dangerous sites will be at the driver's 

discretion. Safe and clear access is the responsibility of the 

property owner/builder.

 

 

 

7.

 

INSTALLATION 

 

 

Always ensure the installation location including the future landscaping provision 

allows for the diversion of storm-water and surface waters away from the system.

 

 

 

 

 

Width

 

 

Height

 

Inlet Height

 

(from bottom of 

tank)

 

Inlet 

Depth

 

(from ground 

level)

 

Required 

Base

 

(5-7mm Drainage 

Gravel/ Sand)

 

Hole 

Width

 

Hole 

Depth

 

TANK 1*

 

2425

 

2700

 

2070

 

530

 

100

 

3000

 

2700

 

TANK 2*

 

2425

 

2700

 

1950

 

650

 

100

 

3000

 

2700

 

 

Refer to Excavation & Lifting Instructions on Pages 9 & 10

 

 

STANDARD  Taylex

® 

ABS5000

 

 

NON TRAFFICABLE LOADS ONLY

 

NON TRAFFICABLE LOADS ONLY

 

 

2425 mm

 

2425 mm

 

100mm of 5mm-7mm drainage gravel or sand

 

100mm of 5mm-7mm drainage gravel or sand

 

100mm 

Inlet

 

Lifting 

Holes

 

Lifting 

Holes

 

100mm 

OutInlet

 

100mm 

Inlet

 

Lifting 

Holes

 

Lifting 

Holes

 

Top of tank to be a minimum

 

of 100mm above landscaped ground level

 

Summary of Contents for ABS5000

Page 1: ...Installation Manual ADVANCED BLOWER SYSTEM 5000 ABS5000 Standard...

Page 2: ...8 9 COMMISSIONING 8 10 EXCAVATION LIFTING INSTRUCTIONS 9 a ABS5000 Excavation Instructions 9 b ABS5000 Lifting Instructions 10 11 ELECTRICAL CONNECTION DIAGRAM 11 12 Note Do not act solely on the basi...

Page 3: ...ced if the ABS5000 is not immediately installed SLIPPERY WHEN WET During cleaning maintenance repair work the surrounding area may become extremely slippery due to spilt water Caution is to be taken w...

Page 4: ...moisture for heavy equipment access Weather conditions 5 MARK OUT To ensure the ABS5000 is installed in the position nominated by the Home Owner Builder the location of the ABS5000 should be marked o...

Page 5: ...n behind the vehicle before placing it into the prepared hole Maximum reach from the rear of the truck to the centre of ABS5000 will vary depending on the size of the crane To enable the ABS5000 to be...

Page 6: ...Page 6 of 13...

Page 7: ...n allows for the diversion of storm water and surface waters away from the system Width Height Inlet Height from bottom of tank Inlet Depth from ground level Required Base 5 7mm Drainage Gravel Sand H...

Page 8: ...inflow outflow direction 1 deviation Backfilling Use sand or excavated material spoil with maximum particle size of 300mm Backfilling of excavation to be completed in not more than 500mm equally dist...

Page 9: ...is completed prior to having the system commissioned Tanks is full of water 5 000lt each Effluent Disposal area is installed Effluent Disposal Area feed line is connected to ABS5000 Tank 2 Electrical...

Page 10: ...13 NON TRAFFICABLE LOADS ONLY NON TRAFFICABLE LOADS ONLY 6000 mm 2425 mm 2425 mm 100mm of 5mm 7mm drainage gravel or sand 100mm of 5mm 7mm drainage gravel or sand 100mm Inlet Lifting Holes Lifting Ho...

Page 11: ...ing Holes 1 Always use a Spreader Bar and ensure it is certified 2 Lower chains through TOP lifting holes provided in the lid of the ABS5000 3 Loop chains through the lifting holes directly below on t...

Page 12: ......

Page 13: ......

Reviews: