5 • USER INSTRUCTIONS
Clean suction foot filter
The suction foot air filter should be cleaned
regularly (once a week, more often if the
environment requires).
1. Remove the suction foot.
2. Carefully clean the air filter using reduced
compressed air.
3. The filter inset MUST be replaced when
excessively dirty or damaged.
4. fit the suction foot with two or four M6/M8
bolts to the suction head, see
Install suction
foot on page
17
. Use a torque between 2-3
Nm for the bolts.
5. Verify function of the lifter.
Clean vacuum pump filter
The vacuum pump filter should be cleaned
regularly (once a week, more often if the
environment requires it).
1. Open the service lid and lift out the filter
unit (a).
2. Open the filter unit (b).
3. Empty the filter unit and remove the filter
inset in an upside-down orientation (c).
4. Carefully clean the filter inset using
reduced
compressed air.
5. The filter inset MUST be replaced when
excessively dirty or damaged.
6. Reassemble the filter unit and put it back in
the service compartment.
7. Verify function of the lifter.
• Clean the vacuum pump filter and suction foot filter regularly. failure to clean the filters may cause
the pump to overheat or reduce lifting capacity.
• Take care to mount the filter unit in the correct orientation during reassembly. Damage to the pump
may occur if the filter unit is mounted upside-down in the filter holder.