BEFORE INSTALLATION
Before installation, decide if the valve will be installed horizontally or vertically. Both options are
available with this valve and use similar installation methods. This guide shows horizontal installation for
illustrative purposes.
Most problems associated with the operation of thermostatic shower valves are caused by debris in the
new pipe work getting into the thermostat. These problems are easily avoided by thoroughly flushing
the pipe work BEFORE the valve is fitted. Failure to do so may invalidate your guarantee.
This valve is designed to be installed in stud constructions using timber of a suitable depth as to allow
the full installation frame to fit onto the stud (Figure 1). The centre point between the two studs will be
the final position of the valve. To ensure successful installation, the frame needs to fit correctly between
the two studs without deforming the frame. If necessary use spacers to create the correct fit.
Figure 1