67
TAURUS ELECTRO
www.pipistrel.si
REV. 3
Power plant, propeller and energy storage
Taurus Electro has a out-runner motor mounted on top of the motor arm and provides direct-drive
to the propeller. The motor is a 3-phase synchronous motor with permanent magnets, exhibits high
torque and above average efficiency ratings. The cooling is provided via incident air. The power con-
troller is mounted inside the fuselage in an IP54 casing and is aircooled via a dedicated cooling duct.
The system is controlled via the color-display EYSY-MAN cockpit interface instrument. It indicates
the drive mode and important parameters to the pilot and provides the interface for engine retrac-
tion and extension. Everything is operated via two (2) toggle switches and a rotatable knob. The
first toggle switch is the system enable (on/off) switch while the second toggle switch is the motor
position selector up/down i.e. extended or retracted. This process is fully automated – the propeller
is positioned and held in place while the motor extends or retracts. The pilot only selects the desired
mode with the toggle switch. The rotary encoder acts as the throttle selector. The ESYS-MAN also
communicates with the Battery-Management-System and delivers information about the state of
charge, battery health information and monitors the charging. All components communicate via the
CAN interface with a proprietary communication protocol.
Motor:
TEMPERATURE °C / ELECTROMOTOR
ELECTRO 40/30
maximum take-off power (1 min)
40 kW
maximum continuous power
30 kW
maximum operating temperature
100° C
maximum ambient temperature
40° C
RPM
ELECTRO 40/30
maximum allowable
2200
take-off rpm (typical)
2150
climb rpm (typical)
1900
Controller:
POWER CONTROLLER
ELECTRO 40/30
maximum operating temperature
75° C
recommended max continuous temperature
45-55° C
WARNING!
DO NOT, UNDER ANY CIRCUMSTANCES, ATTEMPT TO USE ANY OTHER
BATTERIES, OTHER THAN PIPISTREL FACTORY ORIGINAL BATTERY SYSTEM, WITH THIS MOTOR/
CONTROLLER.
Aircraft and systems on board
Summary of Contents for ELECTRO G2
Page 6: ...6 TAURUS ELECTRO www pipistrel si REV 3 This page is intentionally left blank ...
Page 8: ...8 TAURUS ELECTRO www pipistrel si REV 3 This page is intentionally left blank ...
Page 11: ...11 TAURUS ELECTRO www pipistrel si REV 3 3 view drawing General Dimensions in millimeters ...
Page 12: ...12 TAURUS ELECTRO www pipistrel si REV 3 This page is intentionally left blank ...
Page 52: ...52 TAURUS ELECTRO www pipistrel si REV 3 This page is intentionally left blank ...
Page 60: ...60 TAURUS ELECTRO www pipistrel si REV 3 This page is intentionally left blank ...
Page 94: ...94 TAURUS ELECTRO www pipistrel si REV 3 This page is intentionally left blank ...