27
7
FUNCTION
ENTRANCE
CH/PP
ON
Enables the Step-by-Step function on input 19.
OFF
Enables the CLOSING function on input 19.
8
FUNCTION
ENTRANCE
STOP/ ANTI-PANIC
ON
Enables the STOP function on
STOP/ANTI-PANIC
input.
OFF
Enables the
ANTI-PANIC
function on
STOP/ANTI-PANIC
input.
9
INTERLOCK FUNCTION
ON
Enables INTERLOCK function
OFF
Disables INTERLOCK function
10
OPENING PRIORITY
(INTERLOCK)
ON
With ACTIVE INTERLOCK function. Set in ON on the control board
that must have LOW priority.
OFF
With ACTIVE INTERLOCK function. Set in OFF on the control board
that must have HIGH priority.
11
INSIDE SENSOR TEST
ON
Enables internal sensor test – the test is carried out on the input,
PICTURE1
OFF
Disables the test on the input, PICTURE1
12
OUTSIDE SENSOR TEST
ON
Enables external sensor test – the test is carried out on the input,
PICTURE2
OFF
Disables the test on the input, PICTURE2
Dip switch SW2
1
ON
OFF
Keep the Dip switch in OFF
2
ON
OFF
Keep the Dip switch in OFF
3
ON
OFF
Keep the Dip switch in OFF
4
DOORS
DIRECTION
ON
Opening
towards the right
OFF
Opening
towards the left
If the automatic door has a single leaf opening to the right, it is necessary to reverse
the controls of the dip switch 4 as follows: ON: opening towards the left - OFF: opening
towards the right (standard)
5
ON
OFF
Keep the Dip switch in OFF
6
ON
OFF
Keep the Dip switch in OFF
BATTERY CHARGER KEY
Key:
LED steady on;
LED flashing
;
GREEN LED – battery charger
status
off
battery charger off;
flashing every 2 seconds
initial slow charge;
continuous flashing
under fast charge;
flashing every 4 seconds
in backup;
steadily lit
battery charged;
DC19 -
ENGLISH