![tau DC19 Installation Manual Download Page 22](http://html.mh-extra.com/html/tau/dc19/dc19_installation-manual_821505022.webp)
22
11 - 12
PRESENCE DETECTOR
TESTS
11= 24V DC TEST
12= - TEST
Terminals
Input/Output
Door StatusFunction
13 - 17
INSIDE SENSOR (N.O.)
(17= Common)
Closed
Opens in “EXIT ONLY” and “AUTO”.
Opening
None.
Closing
Reverts motion and opens in “EXIT ONLY” and
“AUTO”.
Open
Door won’t close until sensor is released.
In pause
None.
14 - 17
OUTSIDE SENSOR
(N.O.)
(17= Common)
Closed
Opens in “ENTRY ONLY” and “AUTO”.
Opening
None.
Closing
Reverts motion and opens in “EXIT ONLY” and
“AUTO”.
Open
Door won’t close until sensor is released.
In pause
None.
15 - 17
PHOTOCELLS
1
st
PAIR (N.C.)
(17= Common)
Closed
None.
Opening
None.
Closing
Reverts motion and opens.
Open
Door won’t close until photocells are released.
In pause
None.
16 - 17
FOTOCELLULA 2 (N.C.)
(17= Common)
Closed
None.
Opening
None.
Closing
Reverts motion and opens.
Open
Door won’t close until photocells are released.
In pause
None.
CONNECTOR J16:
Terminals
Input/Output Door Status Function
18 - 20
EMERGENCY
(N.C.)
(20=
Common)
Closed
Opens in any program, except in “LOCKED”. When
dip # 1 on SW1 is set on ON opens also in “LOCKED”.
Opening
None.
Closing
Reverts motion and opens.
Open
Door won’t close until input is released.
In pause
None.
19 - 20
CLOSE
/LATCHING
RELAY
(N.O.)
DIP # 7 on SW1 on OFF
(20=
Common)
Closed
None.
Opening
Reverts motion and opens.
Closing
None.
Open
Closes in any program, except in “HOLD OPEN”.
In pause
None.
19 - 20
CLOSE/
LATCHING
RELAY
(N.O.)
DIP # 7 on SW1 on
ON
(20=
Common)
Closed
Opens in any program, except in “LOCK”.
Opening
Reverts motion and closes, except in “HOLD OPEN”.
Closing
Reverts motion and opens, except in “LOCK”.
Open
Closes in any program, except in “HOLD OPEN”.
IMPORTANT: Auto Close function is disabled.
In pause
Closes.
DC19 -
ENGLISH