DIAGNOSTICS LEDs AND BUZZER
DL1
DIAGNOSTIC
DL2 - Red
POWER SUPPLY 12 V
DL3 - Red
POWER SUPPLY 5 V
DL4 - Red
AUX POWER SUPPLY 24 V DC
DL5 - Red
INSIDE SENSOR
DL6 - Red
OUTSIDE RADAR
DL7 - Green
PHOTOCELL 1
DL8 - Green
PHOTOCELL 2
DL9 - Green
EMERGENCY
DL10 - Red
CLOSE/LATCHING RELAY Pushbutton
DL11 - Green
INTERLOCK
DL12 - Green
SIDE SENSOR
DL13 - Green
STOP/ANTI-PANIC
DL1 LED ERRORS
Key
:
LED steady on
;
LED flashing
;
Automation warnings:
green - flashing every 4 seconds
automation closed – everything OK;
green - continuous flashing
automation moving (opening/closing);
green – quick flashing
automation pausing;
green – steadily lit
automation open;
/ alternating green/red - warning
setup to be performed
yellow – QUICK flashing
setup in progress
/
green/yellow – QUICK flashing
Parameter recalculation in progress / program
change
Automation alarms:
red - 1 error
photocell test failed
red - 2 error
obstacle present
red - 3 error
no voltage
red - 4 error
automation in unknown status
red - 5 error
automation timeout
red - 6 error
red - 7 error
wrong parameters (generic error)
red - 8 error
Motor alarms:
yellow - 1 error
yellow - 2 error
motor movement timeout
yellow - 3 error
encoder faulty or disconnected