25
DC16
LOGIC ADJUSTMENTS
Trimmer
Function
Description
TM1
OPENING
SPEED
Adjusts Opening Speed.
TM2
CLOSING
SPEED
Adjusts Closing Speed.
TM3
OPENING
TORQUE
Adjusts Opening Torque.
TM4
CLOSING
TORQUE
Adjusts Closing Torque.
TM5
OPENING
SOFT STOP
Adjusts Length of Opening Soft Stop.
TM6
CLOSING
SOFT STOP
Adjusts Length of Closing Soft Stop.
TM7
AUTO CLOSE
DELAY
Adjusts Auto Close Delay.
Dip switch SW1
1
EMERGENCY
ON
Enables opening with always closed program.
OFF
Disables opening with always closed program.
2
ELECTRO-
LOCK
ON
Enables the electric lock when the automation is closed, regardless
of the selected program.
OFF
Enables the electric lock when the automation is closed only with
the “always closed” program.
3
BATTERY
OPENING
ON
If there is no voltage, the automation performs the manoeuvres
normally. If the battery is flat, the board switches off.
OFF
If there is no voltage, the automation performs the manoeuvres
normally. Before the battery is fully discharged, it performs an
opening manoeuvre.
4
ON
OFF
Keep the Dip switch in OFF
5
TCA
INCREASE
ON
With a high flow of passages, the automatic closing time is auto
-
matically increased.
OFF
Function disabled, the automatic closing time remains unchanged.
6
ON
OFF
Keep the Dip switch in OFF
7
FUNCTION
ENTRANCE
CH/PP
ON
Enables the Step-by-Step function on input 21.
OFF
Enables the CLOSING function on input 21.
8
FUNCTION
ENTRANCE
AUXILIARY
ON
Enables the STOP function on AUXILIARY input.
OFF
Enables the BREAK function on AUXILIARY input.
9
ON
OFF
Keep the Dip switch in OFF
10
ON
OFF
Keep the Dip switch in OFF
ENGLISH
Summary of Contents for DC16
Page 42: ...42 DC16 ...