Dip 9
Dip 10 Automation
Off
Off
ARM up to 400 Kg irreversible
On
Off
Not used
Off
On
ARM250BIR fino a 200 Kg / 4m
reversibili
On
On
Not used
In case of open leaves and in the presence of wind, the D729MA control unit via the Dip
Switch Soft 20 (adjustable with the TAUPROG / T-WIFI (TAU APP), but already preset by the
factory in ON) will try to keep the gate leaves open .
5. MEMORIZATION PROCEDURE
WARNING: After powering the control panel, wait 2 seconds before you start performing the
adjustment operations.
Note: the mechanical stops of the automation must be regulated both in opening and in closing
[see motor instructions].
It is recommended to start the learning process with the gate at 0,5 m from closing mechanical stop.
Press without releasing the P1 and P2 buttons till the DL5 LED starts flashing (yellow):
- the automation starts to open slowly looking for the opening limit gate stop;
If the automation closes instead of opening, stop the run of the gate (by cutting the photo-
cells or closing the STOP contact), invert the polarity of the motor that closes, take the gate
in the closed position (on the mechanical stop) and restart the procedure from the beginning.
Note: if the automation does not work, check the input connections. The DL2, DL3, DL4 green
LEDS must be on.
- once the limit gate stop is reached, the automation starts closing looking for the closing limit gate
stop (in this phase the control unit gathers all the parameters regarding the run);
- the automation carries out one complete opening to optimize the opening power;
- after a short pause, the automation carries out one complete closure to optimize the closing power.
WARNING:
- The procedure can be stopped by pressing the STOP button.
- During the various stages of the operation, if the sensor is activated saving is stopped. To
restart the procedure from the beginning (with the DL5 yellow LED flashing), use the AP/CH
control or the remote control (if programmed).
Please remember that an obstacle during saving is interpreted as a mechanical limit stop
(the system does not start any safety operation, it just stops the motors).
Make sure you don’t stand near the automation during saving.
6. D729MA CHARACTERISTICS
TIMER-OPERATED OPENING AND CLOSING CYCLES
The opening/closing of the automation can be controlled by means of a timer that has a free N.O. output
contact (relay). The timer must be connected to terminals 1 - 2 (OPEN/CLOSE button) and can be programmed
so that, at the desired opening time, the relay contact closes until the desired closing time (when the timer’s
relay contact opens, enabling the automatic closing of the gate).
Note: the automatic closing function must be enabled by setting Dip-switch no. 1 to ON).
OBSTACLE DETECTION
If the obstacle detection function (which can be set through trimmer FR) is activated during an opening ma-
noeuvre, the automation closes approx. 20 cm., if it is activated during a closing manoeuvre, the automation
opens all the way .
WARNING: the control panel logics may interpret mechanical friction as an obstacle.
7. DIAGNOSTICS LED