117
Marchesan Implementos e Máquinas Agrícolas “TATU” S.A.
PST DUO FLEX / PST DUO FLEX SUPREMA
Set-up instructions
Vacuum meter set-up instructions
E
E
Due to the atmospheric pressure and the ambient temperature, the bolt (E) is used to
adjust the vacuum meter to zero.
How to set the vacuum meter to zero:
• Turn off the turbine and wait for the blower to stop;
• Put a screwdriver on the bolt below "ZERO SET" to adjust the vacuum meter;
• Set it to zero with gentle movements;
• The indicator will move farther from zero on a clockwise movement and closer to zero
on a counterclockwise movement;
• Never use sharp objects to adjust, such as a switchblade. They may damage the seal.