3.1 Time zones
The regulator is equipped with the clock, which enables the automatic change of the regulator
operation at different times of day. 24 hrs are divided into 3 time zones (
) and the single time
when no zone is active that is ZONE 0 or BAZA (BASE). Each zone has a start time (OD)/FROM
and an end time (DO)/TILL.
For the regulator factory settings are as it follows:
ZONE 1
FROM 6.00 TILL 8.00
ZONE 2
FROM 14.00 TILL 17.30
ZONE 3
FROM 20.00 TILL 22.30
$1, $2, $3
3.2
Screens
Alarm screens
is not seen till the following emergency situation takes place:
1. Damage of sensor T1 (upper one of CWU).
“
T1
”
shows up. The alarm doesn
’
t work if the sensor
is not installed.
2. Damage of sensor T2 (lower one of CWU).
“
T2
”
shows up.
3. Damage of sensor T3 (of fireplace).
“
T3
”
shows up.
4. The exceeding of
the acceptable temperature of fireplace /
”
TEMP KOM
”
/ defined by
the
“
T.ALARMU
”
parameter
ALARM !!
T1
ALARM !!
TEMP KOM
Emergency situation is accompanied by a broken sound alarm that can be turned off by pressing the
USTAW button.
In emergency of temperature exceeding the pump CO turns on to cool off fireplace.
shows the actual temperature of
fireplace
Screen of fireplace water jacket temperature measurement
It
’
s a stable state that is in order to change it one needs to press the WYBIERZ button
shows the actual temperature in the upper and lower part of the CWU
accumulator.
Screen of CWU temperature
KOMINEK
73.5
0
1...30mins
4mins
1...2
1
1
2
75...89
o
C
85
o
C
1...6
1
1
2
3
4
5
6
t StopCO
Ster CWU
T ALARMU
PrzekSTR
4 Installing the regulator
!
!
!
!
THE REGULATOR SHOULD NOT BE EXPOSED TO WATER AFFECTING.
ITS ENVIRONS OUGHT TO BE CLEAN.
THE PRODUCER DOESN'T TAKE ANY RESPONSIBILITY FOR
DAMAGES CAUSED BY WRONG USAGE OF THE REGULATOR.
Connection diagram of the elements of the regulator is presented on fig. 3
THE REGULATOR IS SUPPLIED BY 230V/50HZ .
THE REGULATOR HAS TO BE CONNECTED TO THE MAINS WITH THE
ANY MOVES REGARDING INSTALLATION SHOULD BE MADE AT
THE DISCONNECTED MAINS.
ZERO-PIN.
FUNCTION
PARAMETERS OF LEVEL 3
NAME
RANGE
FACTORY
SETTING
Pause time of CO pump in cyclical mode. After the time the pump
turns on for 45 secs.
Kind of supply for the CWU accumulator
Temperature sensor T2 (down) controls the supply of CWU
Temperature sensors T1 (up) and T2 (down) control
the supply of CWU accumulator
Fireplace temperature at which alarm turns on.
Switch-on of the relay CONTROL if
fireplace temperature is higher than
„
T.za
ł
CO
”
„
T.za
ł
CWU
”
fireplace temperature is higher than
fireplace temperature is higher than
CWU temperature measured by T2 sensor is higher
than
“
TminCWU
”
CWU temperature measured by T1 sensor is higher than
CWU temperature measured by T2 sensor is higher than