TATAREK RT-08K User Manual Download Page 5

5

Za

łą

czony przeka

ź

nik STEROWANIE

Wskazanie górnego czujnika CWU

Wskazanie dolnego czujnika CWU

Wskazanie czujnika kominka

CO

*

KOM

?

CWU

80

o

73

o

68

o

8

3.1 Time zones

The regulator is equipped with the clock, which enables the automatic change of the regulator

operation at different times of day. 24 hrs are divided into 3 time zones (

) and the single time

when no zone is active that is ZONE 0 or BAZA (BASE). Each zone has a start time (OD)/FROM
and an end time (DO)/TILL.

For the regulator factory settings are as it follows:

ZONE 1

FROM 6.00 TILL 8.00

ZONE 2

FROM 14.00 TILL 17.30

ZONE 3

FROM 20.00 TILL 22.30

$1, $2, $3

3.2

Screens

Alarm screens

is not seen till the following emergency situation takes place:

1. Damage of sensor T1 (upper one of CWU).

T1

shows up. The alarm doesn

t work if the sensor

is not installed.
2. Damage of sensor T2 (lower one of CWU).

T2

shows up.

3. Damage of sensor T3 (of fireplace).

T3

shows up.

4. The exceeding of

the acceptable temperature of fireplace /

TEMP KOM

/ defined by

the

T.ALARMU

parameter

ALARM !!

T1

ALARM !!

TEMP KOM

Emergency situation is accompanied by a broken sound alarm that can be turned off by pressing the
USTAW button.
In emergency of temperature exceeding the pump CO turns on to cool off fireplace.

shows the actual temperature of

fireplace

Screen of fireplace water jacket temperature measurement

It

s a stable state that is in order to change it one needs to press the WYBIERZ button

shows the actual temperature in the upper and lower part of the CWU

accumulator.

Screen of CWU temperature

KOMINEK

73.5

0

1...30mins

4mins

1...2

1

1

2

75...89

o

C

85

o

C

1...6

1

1
2
3

4

5

6

t StopCO

Ster CWU

T ALARMU

PrzekSTR

4 Installing the regulator

!

!

!

!

THE REGULATOR SHOULD NOT BE EXPOSED TO WATER AFFECTING.

ITS ENVIRONS OUGHT TO BE CLEAN.

THE PRODUCER DOESN'T TAKE ANY RESPONSIBILITY FOR

DAMAGES CAUSED BY WRONG USAGE OF THE REGULATOR.

Connection diagram of the elements of the regulator is presented on fig. 3

THE REGULATOR IS SUPPLIED BY 230V/50HZ .

THE REGULATOR HAS TO BE CONNECTED TO THE MAINS WITH THE

ANY MOVES REGARDING INSTALLATION SHOULD BE MADE AT

THE DISCONNECTED MAINS.

ZERO-PIN.

FUNCTION

PARAMETERS OF LEVEL 3

NAME

RANGE

FACTORY
SETTING

Pause time of CO pump in cyclical mode. After the time the pump
turns on for 45 secs.

Kind of supply for the CWU accumulator

Temperature sensor T2 (down) controls the supply of CWU

Temperature sensors T1 (up) and T2 (down) control
the supply of CWU accumulator

Fireplace temperature at which alarm turns on.

Switch-on of the relay CONTROL if

fireplace temperature is higher than

T.za

ł

CO

T.za

ł

CWU

fireplace temperature is higher than

fireplace temperature is higher than

CWU temperature measured by T2 sensor is higher
than

TminCWU

CWU temperature measured by T1 sensor is higher than

CWU temperature measured by T2 sensor is higher than