TATAREK RT-08K User Manual Download Page 4

4

9

PRIO-

ZEGAR-

Faster reaching the readiness of CWU accumulator by limiting heat obtain by heating

system. The pump CO works cyclically. Turning off the pump CWU after supplying the accumulator
causes the comeback of normal operation of the pump CO

beyond time zones the pump operates like in the ZA

Ł

mode and in time zone like PRIO

Fig.3 Electrical scheme

T1

Upper temperature sensor of solar collector (option)

T2

Lower temperature sensor of CWU accumulator

T3

Temperature sensor of fireplace water jacket

P1

Pump supplying CWU accumulator from a fireplace

P2

Pump of the primary side of heat exchanger (it operates if P1 or P3 is activated)

P3

Circulating pump CO

Pump P1
230V/50Hz

Pump P3
230V/50Hz

MAINS

230V/50Hz

Pump P2
230V/50Hz

+

+

+

Temperature
sensors

T1

T2

T3

CONTROL

2.4 Output

CONTROL

The regulator is equipped with the relay CONTROL whose contacts can be used e.g. to switch

off another heat source when a fireplace works. The

PrzekSTR

parameter defines the function of

the relay more precisely

3 Service of the regulator

There are elements on the control panel (fig. 2).
The state is presented on the text display (1). The screens inform about the operation of devices,
temperature of sensors; they make it possible to change the parameters etc..The change of screen is
done by pressing the WYBIERZ button (3). If this is the screen that is able to change a parameter,
press the USTAW button, which causes blinking of the parameter field to be changed. By pressing

+

(2) or

-

(4) one can alter its value.

If there are more parameter fields on the screen (e.g. setting the clock) then one will go among them
by pressing the WYBIERZ button (3).

Fig.2 Control panel view

1.

Text display

2.

Increase button

3.

Choice button of parameter

4.

Decrease button

5.

Confirm button

By clicking the USTAW button (5) one confirms the changes - the parameter field stops blinking.
The changed parameter not confirmed for 10 secs is not accepted by the regulator and it recalls a
previous value of the parameter.

1

2

3

4

5