TATAREK RT-08K User Manual Download Page 1

Zakład elektroniczny TATAREK Jerzy Tatarek

USER MANUAL

1

RT-08K

REGULATOR

OF

HEATING SYSTEM WITH FIREPLACE

12

RT08K/2008/TITANIUM/ANG

The regulator controls heating system based on a water jacket fireplace which is a heat source. The
heat receivers are: applicable warm water accumulator (CWU) and central heating system (CO).

1.Basic technical parameters:

Power

230V/50Hz

Power consumption without load

5W

Max connection power

750W

Operation conditions

0 50 C, humidity 10 90%

(No condensation)

Housing protection class

IP41

Fuse

6,3A/250V

Number of outputs to control pumps

3 * 250W/230V/50Hz

Number of nonvoltage outputs

1

Number of water temperature sensors

3 * KTY81 (0...+100 C )

Temp. measurement precision

2 C

Temp. measurement resolution

0,5 C

Number of time zones

4

÷

÷

o

o

o

o

Zakład elektroniczny TATAREK Jerzy Tatarek

50-559 Wroclaw,

wieradowska st,

ph. (071) 367-21-67, 373-14-88, fax 373-14-58;

Bank account: BZ WBK S.A. WROC

Ł

AW 6910901522-0000-0000-5201-9335

www.tatarek.com.pl.; e-mail: [email protected]