Important! Switch the machine off when you:

• e.g. carry out cleaning or maintenance work, or convert the machine to 

another function

• store it in a suitable room to avoid any unauthorised use of the unit
• leave it standing without supervision

To do so, disconnect the power supply cord from the wall socket and stop the 

machine from rolling away (e.g. by fixing a wedge).

Store the machine in a dry, dust-free room with a corrosion-free atmosphere.

The temperature must not fall below +10 °C or 35 °C. Low 

temperatures, damp and dust can significantly reduce the service life of the 

electrical components.

Original EU Declaration of Conformity

We hereby declare that the product described below conforms to the relevant 
safety- and health-related requirements of the appropriate EU Directive in both 
its basic design and construction and in the version marketed by us.
If  any modifications are carried out on the product that have not been agreed 
with us, this declaration will no longer be valid.

Applicable EU Directives:

Directive 2006/42/EC | Directive 2004/108/EC

Harmonised standards applied:

EN 60335-1/ EN 60335-2-72 / EN 62233 / EN 55014-1 / EN 55014-2 / 
EN 61000-3-2 / EN 61000-3-3

It is ensured through internal measures that series-production units conform at 
all times to the requirements of current EU Directives and relevant standards.

Download Link for the original EU Declaration of Conformity:

http://www.espares.diversey.com/manuals

Caution:

This machine should only be operated with a positive ground 
(earth) connection!

Only use the machine on level floors or on gradients of 2% or less.

This symbol on the machine indicates that it is not suitable for use 

on surfaces with greater gradients.

The tank cap must be closed when moving or driving the machine.

 Noise emissions and vibrations:

TASKI machines and units have been designed so that any 
danger to health through the noise emitted or through vibrations 
can be excluded according to the current state of knowledge. 
Refer to the technical information on page 29.

2%

Designation:

Automatic machine for the treatment of floors for 
commercial purposes

Product:

scrubber dryer

Model:

swingo 455E

Model:

CO455.0

Serial number:

Refer to the rating plate on the machine

Trademark:

Manufacturer:

Diversey Europe Operations B.V. - 1083 HJ Amsterdam 
- Netherland

Responsible for documentation:

Angelo Sabatino
Mgr Regulatory Affairs
Diversey Switzerland Services GmbH
Eschlikonerstrasse
9542 Münchwilen TG

Summary of Contents for swingo 455E

Page 1: ...swingo 455E V003 12089 85 1223 I25 I24 I23 I22 I21 I20 I19 I18 I17 I16 I15 tr sv pt pl no nl it fr fi es en de cz cn 12089 85 ...

Page 2: ...ly inflammable materials such as petrol solvents fuel oil dusts etc are stored or processed The electrical or mechanical components could lead to the ignition of these materials This machine must not be used in rooms that are subject to electro magnetic loading electro smog STOP t STOP STOP STOP Do not use this machine to vacuum toxic poisonous caustic or irritating substances e g hazardous dusts ...

Page 3: ...EN 62233 EN 55014 1 EN 55014 2 EN 61000 3 2 EN 61000 3 3 It is ensured through internal measures that series production units conform at all times to the requirements of current EU Directives and relevant standards Download Link for the original EU Declaration of Conformity http www espares diversey com manuals Caution This machine should only be operated with a positive ground earth connection On...

Page 4: ...ch 28 Solution switch Preparation for operation Operation Attaching tools Check that the brush has not fallen below the red mark or a brush length of 1 cm the pad for wear before using Attach squeegee 1 2 3 4 5 6 7 8 9 10 11 12 13 14 max 60 C max 140 F 15 16 17 18 19 21 22 23 24 25 26 27 28 20 Switch the machine off and pull the power supply cord out of the mains socket Working with worn out damag...

Page 5: ...clothing while working with this machine Lower the squeegee Unlatch the foot lever and slowly lower the tool Plug the power supply cord into the mains socket Switch the machine on main ON OFF switch The main switch lights up Push the cleaning solution switch The main switch lights up Push the suction unit switch The indicators light up briefly Adjust the volume of the cleaning solution max 60 C ma...

Page 6: ...ge to the floor coating Switch the machine off Once the solution tank has been drained screw the yellow cap from the solution tank filter and pull it away from its holder Rinse the filter under running water If necessary the filter should be descaled with a 10 TASKI calcacid solution The filter is lower than the tank outflow A residual amount of solution will flow out once the filter cap has been ...

Page 7: ... and screw the star grip in place again Switch the machine off and pull the power supply cord out of the mains socket The yellow suction filter can be easily removed quick fit seal Clean it under running water using a brush let it dry out well Brush the yellow suction filter with a soft brush or remove the fluff with a cloth 3 1 2 Malfunction Possible causes Troubleshooting page Machine does not r...

Page 8: ...kg Solution tank nominal 22 l Recovery tank 25 l Tools 1 x 43 cm Brush rpm 160 min 1 Brush pressure 25 kg Dimensions L x W x H 139x69x110 cm Noise emission level according to ISO 11201 70 dB A Total vibration value of hand arm vibration to ISO 5349 0 5 m s2 Splash water protection IPX4 Electrical protection class I Nr Article CO455 0 7510829 Pad drive Instalok 43cm X 8504750 Scrubbing brush 43cm n...

Reviews: