End of operation

Brush unit button (optional):

Pedal brush unit (optional):

Drain the recovery tank / solution tank

The disposal of the dirty water or the cleaning solution must be carried out in 
accordance with the appropriate national regulations.

Clean the recovery tank / solution tank

Clean solution tank filter

Cleaning the tools

Brush unit button (optional):

Pedal brush unit (optional):

Swingo 1250B model:

Swingo 750B model:

Removing and cleaning the squeegee

• Stop the flow of solution.

• Drive a few metres so that the tools rotate further for a short time. You will 

avoid dripping by doing this.

Very important when using contact pads!

• Press the brush unit button to raise the tool.

• Press down the pedal and lock it in place to 

raise the tool.

• Drive on a few metres further in order to pick up the remaining dirty water.

• Raise the squeegee.

Allow the suction unit to continue running until 
the rest of the dirty water has been sucked into 
the hose.

• Switch off the suction unit first, and then the 

keyswitch.

Always drain and clean the recovery tank every time you use the 
machine.

If the dirty water is allowed to stand, unpleasant smells and 
deposition of the dirt will take place after a few hours.

• Switch the machine off.
• Remove the hose from its holder.

Open the red or blue cap situated near the handle and lower the 
end of the hose slowly to drain the solution out.

• Switch the machine off.
• Open the lid until the self support locates on the tank wall.
• Remove the coarse dirt sieve (yellow), empty and clean it.
• Thoroughly rinse out the recovery tank with clean water.
• Then thoroughly rinse out the solution tank with clean water.
• Check the float is functioning correctly and that the suction filter (yellow) is 

clean.

In case of damage or soiling of the float and suction filter, please refer to 
Page 28.

• After draining and cleaning, screw the red and blue caps on again, and hang 

the hoses from their holders again.

Caution:

Clogged filters reduce the flow of the cleaning solution. As a 
consequence you may damage the floor coating.

• Switch the machine off.

• Once the solution tank has been drained, screw 

the yellow cap from the solution tank filter and 
pull it away from its holder.

• Rinse the filter under running water.

If necessary, the filter should be descaled with a 10% TASKI calcacid 
solution.

The filter is lower than the tank outflow. A residual amount of 
solution will flow out once the filter cap has been unscrewed.

• Refit the solution filter.

• Switch on the keyswitch.

The indicators light up briefly.

• Press the brush unit button to raise the tool.

• Switch the machine off using the keyswitch and remove the key.

• Switch the machine off using the keyswitch and remove the key.

• Press down the pedal and lock it in place to 

raise the tool.

• Press the tool ejection handle briefly but firmly 

with your foot.

• Clean the tools with water.

• Turn the tool anticlockwise away from the tool 

coupling using your foot. 

• Clean the tools with water.

• Switch the machine off.
• Pull the suction hose away from the squeegee support.

• Raise the squeegee and loosen the fixing 

screws on the squeegee.

• Assemble the squeegee and tighten the fixation 

screws.

• Clean the squeegee with water using a brush.

Summary of Contents for swingo 1250B

Page 1: ...o 750B 1250B Power V008 12088 69 0702 I25 I24 I23 I22 I21 I20 I19 I18 I17 I16 I15 I14 I13 tr sl pt no it hr fr fi es en de da da 2 de 12 en 22 es 32 fi 42 fr 52 hr 62 it 71 no 81 pt 91 sl 101 tr 111 12088 69 ...

Page 2: ...anical components of the machine could lead to ignition of these materials Do not use this machine to vacuum toxic poisonous caustic or irritating substances e g acids alkalis hazardous dusts etc The filter system will not adequately retain these kinds of materials A possible impairment of the health of the user and of third parties cannot be excluded While operating the machine take note of the s...

Page 3: ...d relevant standards The signatories act on behalf of company management and with full power of attorney Overview 1 Speed control 2 Squeegee lowering device 3 Emptying hose for solution tank blue cap 4 Emptying hose for recovery tank red cap 5 Disconnector charger jack coded 6 Pedal brush unit optional 7 Squeegee settings 8 Squeegee 9 Hour counter optional 10 Lock battery compartment optional 11 T...

Page 4: ... Leave the power supply cord connected to the mains until you use the machine again The on board charger unit automatically monitors and charges the batteries The energy consumption in the mode is limited to a few milliwatts If a fault occurs during the charging process as the result of a defect in the charging unit an interruption of a cable or a defective battery cell the red indicator will ligh...

Page 5: ...e and lift the tank until it rests on the tank self support Hold the tank and press the tank support inwards Now lower the tank until it locates into place Connect the battery to the machine with the battery disconnection socket Raise the squeegee Switch on the keyswitch The indicators light up briefly The battery indicator displays that the machine is ready for operation on malfunction see page 2...

Page 6: ...ible filling level Page 23 Caution Wear protective gloves goggles and the corresponding protective work clothing when handling chemical products Caution Using other chemicals e g chemicals containing solvents chlorine hydrochloric acid and hydrofluoric acid can damage or destroy the machine Dosage Tank capacity Dosing aid 0 5 1 2 1 x 1 2 MAX 1 x MAX 1 1 2 1 x MAX 2 x 1 2 MAX 2 x MAX 1250 750 max 6...

Page 7: ... the tank wall Remove the coarse dirt sieve yellow empty and clean it Thoroughly rinse out the recovery tank with clean water Then thoroughly rinse out the solution tank with clean water Check the float is functioning correctly and that the suction filter yellow is clean In case of damage or soiling of the float and suction filter please refer to Page 28 After draining and cleaning screw the red a...

Page 8: ...he machine with a damp cloth 28 Clean the tank lid seal check for cracks and re place if necessary Maintenance programs by TASKI service made by TASKI technician In order to ensure operational reliability and availability for use the service must be carried out when the service indicatior lights up factory setting 450 working hours or at least once a year Under rough or extreme working conditions ...

Page 9: ...for the dimensions and weights A correct angle has been achieved when the tip of the rear blade x is distributed over the complete width of the suction unit B A x x 4 3 1 2 4 3 Malfunction Possible causes Troubleshooting page Machine does not run Maschine switched off Switch on the keyswitch 23 Connect the battery to the machine with the battery disconnection socket 23 Battery mains unit malfuncti...

Page 10: ...rush rpm 195 165 min 1 Brush pressure 46 35 kg Dimensions L x W x H 135x77x119 112x68x116 cm Rated power 1000 900 W Assessed sound level LPA according to EN 60704 1 58 58 dB A The assessed effective acceleration value according to ISO 5349 0 5 0 5 m s2 Splash water protection IPX3 IPX3 Electrical protection class without battery charger only model type CO1250 1 CO1250 2 III Electrical protection c...

Page 11: ...31 I25 I24 I23 I22 I21 I20 I19 I18 I17 I16 I15 I14 I13 tr sl pt no it hr fr fi es en de da Dimensions of the machine All dimensions in centimetres swingo 1250 swingo 750 119 77 58 135 116 68 46 112 ...

Page 12: ... Ltd Ballyfermot office Westlink industrial estate Kylemore road Dublin 10 Tel 353 1 626 11 82 Fax 353 1 626 20 13 IT JohnsonDiversey S p A Via Meucci 40 20128 Milano Tel 39 02 25 80 32 33 Fax 39 02 25 92 255 MT Forestals Appliances Ltd The Strand SLM 07 Sliema Tel 356 21 344 700 7 Fax 356 21 344 709 NL JohnsonDiversey B V Maarssenbroeksedijk 2 P O Box 40441 3504 AE Utrecht Tel 31 30 247 69 11 Fax...