TASCAM HS-P82
57
Message
Details and responses
Remarks
Digital Input Error
AES1-2 (Unlocked)
AES3-4 (no signal)
AES5-6 (not audio)
AES7-8 (unmatched Cbit)
An error occurred with the digital input
selected for the input signal.
• Unlocked:
not synchronized with system
• no signal:
no signal is being input
• not audio:
Cbit information of input signal is
not audio
• not professional:
Cbit information of input signal is
consumer
• unmatched Cbit:
other Cbit information of input
signal is different from actual
operation mode
External Clock Lost,
Switched to Internal
Synchronization with an external clock
was disrupted, so the internal clock was
activated.
External Clock Regained
Switch to External?
Synchronization with an external clock
became possible again.
EXTERNAL DC Power Lost,
Switched to INTERNAL BATTERY
External DC power was lost, so the internal
battery was activated.
EXTERNAL DC power
now available,
Switch to EXTERNAL DC?
While operating using the internal battery,
external DC power became available.
EXTERNAL DC Voltage too low,
Switched to INTERNAL BATTERY
The voltage of the external DC battery
became low, so the internal battery was
actived.
Input Volume Locked
Input Volume
is locked
The input volume control has been locked to
prevent misoperation.
INTERNAL BATTERY Power Lost,
Switched to EXTERNAL DC
The internal battery was removed, so the
external DC power source was activated.
INTERNAL
BATTERY
Voltage
too
low,
Switched to EXTERNAL DC
The voltage of the internal battery became
low, so the external DC power source was
activated.
Last loaded project has
no scenes.
Please make new scene.
The most recently loaded project does not
have any scenes. Create a new scene.
Last loaded project
cannot be found.
Please select a project.
The last selected project cannot be found.
Select a different project.
Last loaded scene
cannot be found.
Please select a scene.
The last selected scene cannot be found.
Select a scene.
Load selected project?
""pppppppp""
Confirm that you want to load the selected
project.
pppppppp = name of project to load
Load selected Scene?
""ssssssss""
Confirm that you want to load the selected
scene.
ssssssss = name of scene to load
Load selected Take?
""tttttttt""
Confirm that you want to load the selected
take.
tttttttt = name of take to load
Loading Project...
The project is loading.
Loading Scene...
The scene is loading.
Loading Take...
The take is loading.
Lost all power.
Shutdown automatically
in 20 seconds.
All power sources have been lost. The unit
will automatically shut down in 20 seconds.
Make new scene?
""ssssssss""
Confirm that you want you want to make a
new scene.
ssssssss = scene name
Make Scene failed
Creation of the scene failed.
Making Scene...
The scene is being created.
Mark Point set
The mark has been created.
New Scene Name must not
start with ""@""
The scene name is not allowed. A scene
name must not start with the "@" mark.
No Call Point
The call point does not exist.