4 – Operation
28
TASCAM DM-24 Automation
Auto Revert Choices:
With
AUTO REVERT — TRIM
enabled, the automation
system stops trimming mix moves automatically per
control without the need to stop trimming manually.
In this case, controls stop trimming mix moves at dif-
ferent times, depending on when they were released
(faders) or when movement ended (POD controls).
In the case of the touch-sensitive faders, the revert
starts when the fader is released. In the case of POD
controls, revert starts when the
CONTROL SENSE
TIMEOUT
has expired without movement of the con-
trol.
CONTROL SENSE TIMEOUT
allows the POD con-
trols to respond as if they are touch-sensitive even
though they are not.
When a Revert occurs, the control smoothly matches
back to its previous data based on the amount of
Revert Time set. That previous data could be a con-
trol’s Static position or a control’s Dynamic mix
moves. See the diagrams below to understand how
this works:
Figure 20 – Trimming fader moves with Auto Revert enabledl
Figure 21 – Trimming POD moves with Auto Revert enabled.
8 sec
8 sec
+12
+6
+3
0
-3
-6
-12
+12
+6
+3
0
-3
-6
-12
1 sec
2 sec
3 sec
4 sec
5 sec
6 sec
7 sec
1 sec
2 sec
3 sec
4 sec
5 sec
6 sec
7 sec
-9
Existing Fader Move
Mix Move
Raise Fader
Release Fader
Revert
Time
Hold Fader
8 sec
8 sec
Control
Sense
Timeout
+12
+6
+3
0
-3
-6
-12
+12
+6
+3
0
-3
-6
-12
1 sec
2 sec
3 sec
4 sec
5 sec
6 sec
7 sec
1 sec
2 sec
3 sec
4 sec
5 sec
6 sec
7 sec
-9
Existing POD Move
Mix Move
Move POD
Release POD
Revert
Time
POD Movement