TASCAM CD-01U/CD-01U PRO RS-232C Protocol Specifications
19
TEAC Corporation
5-4. PITCH CONTROL DATA RETURN
Transmitted in response to a PITCH CONTROL DATA PRESET command [25] with the request data
([FF]) to show the currently set Pitch Control value.
Command
A5
Data
4 bytes
Request command PITCH CONTROL DATA PRESET [25]
Data 1
Data 2
Data 3
Data 4
Description
Remarks
0
1
Positive (+) value
Negative (-) value
N2
N3
N1
Preset %
N1: Tens digit of pitch control value
N2: Units digit of pitch control value
N3: 1
st
decimal of pitch control value
Sample) 2310: -2.3%
5-5. FADE IN/OUT TIME RETURN
Transmitted in response to a FADE IN/OUT TIME PRESET command [2E] with the request data ([00FF]
or [01FF]) to show the currently set the Fade In and Out time.
Command
AE
Data
4 bytes
Request command FADE IN/OUT TIME PRESET [2E]
Data 1
Data 2
Data 3
Data 4
Remarks
0
0
Tens digit of Fade In time
Units digit of Fade In time
Fade In time
0
1
Tens digit of Fade Out time
Units digit of Fade Out time
Fade Out time
5-6. AUTO CUE SELECT RETURN
Transmitted in response to an AUTO CUE SELECT command [30] with the request data ([FF]) to show
the currently set the Auto Cue mode status .
Command
B0
Data
2 bytes
Request command AUTO CUE SELECT [30]
Data 1
Data 2
Description
Remarks
0
0
Auto Cue Off
Auto Cue function is turned off
0
1
Auto Cue On
Auto Cue function is turned on
5-7. EOM TRACK TIME RETURN
Transmitted in response to an EOM TRACK TIME PRESET command [32] with the request data ([FF])
to show the currently set EOM time.
Command
B2
Data
2 bytes
Request command EOM TRACK TIME PRESET [32]
Data 1
Data 2
Description
Remarks
N1
N2
Sec
N1: Tens digit of EOM time
N2: Units digit of EOM time
00=Off