TASCAM CD-01U/CD-01U PRO RS-232C Protocol Specifications
12
TEAC Corporation
4-14. FADE IN/OUT TIME PRESET
Sets the fade in and out time from 1 to 10 seconds in 1 second steps.
When this command is transmitted with request data ([00FF] or [01FF]), the controlled device returns
the FADE IN/OUT TIME RETURN command [AE].
The FADE mode is turned on and off using the FADE IN/OUT SELECT command [3E].
Command
2E
Data
4 bytes
Return
FADE IN/OUT TIME RETURN [AE]
Data 1
Data 2
Data 3
Data 4
Remarks
0
0
Tens digit of Fade In time
Units digit of Fade In time
Sets the Fade In time
0
0
F
F
Requests the Fade In
time
0
1
Tens digit of Fade Out time
Units digit of Fade Out time
Sets the fade Out time
0
1
F
F
Requests the Fade
Out time
·
If the specified data is other than described above, the controlled device sends ILLEGAL [F2].
·
If the specified data is out of range, the controlled device sends ILLEGAL [F2].
4-15. AUTO CUE SELECT
Turns the Auto Cue function on and off.
When this command is transmitted with request data ([FF]), the controlled device returns the AUTO
CUE SELECT RETURN command [B0].
The Auto Cue level is set using the AUTO CUE LEVEL PRESET command [20].
Command
30
Data
2 bytes
Return
AUTO CUE SELECT RETURN [B0]
Data 1
Data 2
Description
Remarks
0
0
AUTO CUE MODE OFF
Turns the Auto Cue function off
0
1
AUTO CUE MODE ON
Turns the Auto Cue function on
F
F
Auto Cue mode status request
Requests the Auto Cue mode status
·
If the specified data is other than described above, the controlled device sends ILLEGAL [F2].
4-16. EOM TRACK TIME SELECT
Sets the EOM (End of message) time.
When this command is transmitted with request data ([FF]), the controlled device returns the EOM
TRACK TIME RETURN command [B2].
The EOM time should be set to 00, 05, 10, 15, 20, 25, 30, or 35.
Command
32
Data
2 bytes
Return
EOM TRACK TIME RETURN [B2]
Data 1
Data 2
Description
Remarks
N1
N2
Sec
N1: Tens digit of EOM time
N2: Units digit of EOM time
(00, 05, 10, 15, 20, 25, 30, or 35)
F
F
EOM time request
Requests the EOM time
·
If the specified data is other than described above, the controlled device sends ILLEGAL [F2].