32
TARGET FEED MASTER
TARGET FEED MASTER rev.09
Blend Curve Settings
Select the desired house from the main menu using the arrow keys.
Press the right-arrow key.
Select the "
5. Blend curves
" menu then press the right-arrow key.
Accessible if blends are used (s. 5.8.2).
Press the down-arrow key to select
the first day of the curve then set it
to the desired value using the adjust-
ment buttons.
Press the down-arrow key then use the adjustment buttons to select
the feed blend that is distributed on the first day of the curve.
Press the down-arrow key to select the second point of the curve.
Proceed in similar fashion to set the day at which each point starts and
the feed blend associated with each point. If ten points are not needed,
repeat the last blend for each unnecessary point.
Once the ten points are correctly set,
press the up-arrow key to select "
Use
curve?
" menu. Select "
Yes
" to enable
the curve.
4.5 Blend Curve
Use curve ? No
1.Da 1 Blend 1
2.Da 25 Blend 2
4.5 Blend Curve
Use curve ? Yes
1.Da 1 Blend 1
2.Da 25 Blend 2
33
TARGET FEED MASTER
TARGET FEED MASTER rev.09
5.6 TIME CLOCKS
The controller has 8 time clock output, using the real-time clock, to control
various devices such as lights or feed loops. Each output can perform up to
10 cycles per day.
If the
Timed Feeding
distribution method is selected (to feed
the birds according to a timer), Time Clock 1 is automatically
assigned to control the output auger in house 1; Time Clock 2
controls the output auger in house 2 (if applicable). Refer to
section 5.8.2 to select the proper feed distribution method.
Use the arrow keys to select the
"
6. Time Clocks
" from the main menu.
Accessible if time clocks are enabled (s.
5.8.2).
Use the arrow keys to select the de-
sired time clock. The first start time
flashes on the display. Use the
adjustment buttons to set it to the
desired value.
Press the down-arrow key once. The first stop time flashes on the
display. Use the adjustment buttons to set it to the desired value.
Proceed the same way to set all 10 start and stop times of the selected
clock output. If 10 cycles are not required, set the start and stop times
of unused cycles to the same value.
Feed Weigher and
Mixer VX.X
6. Time Clocks
On 1 6:00 Off 6:30
On 2 8:45 Off 9:30
On 3 9:45 Off 11:00
!
WARNING
START TIME = 8:00
STOP TIME = 10:30
ON
OFF
START TIME / STOP TIME DEFINITION