52
ECO II FEEDING rev.06
ECO II FEEDING
7
CLOCK OUTPUTS
The controller has eight timer outputs to control various devices using the real-time
clock. Each outputs has 12 cycles defined using start and stop times.
Select
8. Time clocks*
* Available if time clock outputs have been enabled in
the installation setup (s. 5.3).
• Select a clock output
The following parameters are associated
with the chosen clock output and must
be set separately for each clock output
in use.
• Set the start and stop times for each 12
cycles of the selected clock output. Set
the start and stop times of unused cycles
to the same value.
Main Menu
7.
Current status
8.
Time clocks
Time Clocks
Exit: Press BACK
Change: Press Modify
Press to Select an item
Select Time clock #
1
Start Time 1
12:00A
Stop Time 1
12:00A
Start Time 2
12:00A
Stop Time 2
12:00A
Start Time 3
12:00A
Stop Time 3
12:00A
(...)
Start Time 12
12:00A
Stop Time 12
12:00A
25
ECO II FEEDING rev.06
ECO II FEEDING
4.
USER INTERFACE
4.1
Location of the Controls
LARGE LCD DISPLAY:
The large LCD screen is used to display the various
parameters and menus. The contrast of the screen
can be adjusted using the potentiometer located
behind the display. Open the front cover to access
the potentiometer. If no potentiometer is located
behind the front panel, access the transfer menu
to change the screen contrast (see chapter 11).
The
Current Status
menu is automatically selected
after 4 minutes of inactivity.
ALARM STATUS LED:
The alarm status led turns on when an alarm con-
dition is detected; it flashes if an alarm condition
has occurred and has been restored by itself.
-
+
LCD CONTRAST
POTENTIOMETER
(opt.)