background image

- hold the master until beep 7.
The alarm will respond informing:

7) Set time to lockout (TW10 only)

    

3 Beeps

 = Blocking in 3 Minutes

- With the door open, turn the ignition on.

    1 Beep

   = Blocking in 1 Minute

    

2 Beeps

 = 2 Minute Lockout

To change, press the Master key the number of times referring to the desired time. Each time 
the Master is pressed, the alarm confirms  with 1 beep. After turning the ignition, off  the alarm 
will confirm the new setting with beeps.

+

ON

START

OFF

Configure

Select the Beep 7 function

IGNITION

MASTER

DOOR OPEN

1X = 1 minute
2X = 2 minutes
3X = 3 minutes

MASTER

+

+

+

Enable Secret Button Lock Function:

- With the door open, switch on the ignition.

    2 Beeps

 = Secret button Function 

OFF

- Hold the master pressed until beep 6.
- The alarm will respond informing:
    

1 Beep

   = Secret button Function 

ON

+ +

IGNTION

ON

START

OFF

MASTER

DOOR OPEN

+

configure

   1X enable
   2X disable

Select the Beep 6 function

Attention: 

Function canceled from factory, It is required to be enabled by Beep 8.

6) Lock by Secret Button - required to be enabled by master. (TW10 only)

ATTENTION: In this case, it will not be possible to cancel the triggering by the control.

Operation:

With the ignition on and the doors closed, press the master key for 1 second. Otherwise, Secret Button Lock 
will be enabled. After the programmed time, (according to the Beep 7 setting), the ultrasound LED starts 
blinking, the audio system will be turned off, the siren and turning lights will go off, another 20 seconds, the 
engine will begin  failing until it is definitively Locked .To cancel the lock, press the master. 

6.1) Valet Function (only for TW10 - for Secret Button Lock)

To cancel the Valet function and return to normal operation,

It is used when leaving the vehicle in a parking lot, for example, without the need to indicate to the location of 
the Master (Secret Button) to the valet.

Operation:

With the door closed, turn off the ignition and hold the Master pressed 
for 3 seconds. The ultrasound LED will flash 3 times confirming activation. 

turn the ignition on  with the door closed and press the Master for 1 second.

+ +

IGNIÇÃO

OFF

ON

START

OFF

MASTER

DOOR CLOSED

3 Seconds

 After turning  the ignitionoff , the alarm will confirm the new setting with beeps.

To change, press the Master key once to Enable or 2 times to Disable.

03

MASTER

+

Summary of Contents for Tarsafe TW10

Page 1: ...TW10 TW10 SB MANUAL AUTOMOTIVE ALARM Without Lock ...

Page 2: ...hts Output Lock Unlock and Auxiliary Outputs Sound control and dedicated Siren Configurable output for activating locks and original power windows 9 to 16 Volts 6 to 25 mA Max 20 A 2 x 70W with digital protection Max 200 mA ground signal Max 200 mA positive signal Universal Fiat Line VW G5 G6 G7 VW UP and Mobi 3 Composition BASIC ALARM OPERATION When turning on the alarm by remote control if the ve...

Page 3: ...A HolddowntheONandOFFkeys 3blinks lineG1toG34flashes lineG4andforward B ReleaseafterLEDgoesout C TheLEDwillflashinformingthenewcodesystem RegisterNEWcontrolintheAlarmCenter Itispossibletorecordupto4controls whenrecordingthe5ththefirstonewillbeerased PROCEDURE Withthedooropen switchontheignition Toexitsetup turnofftheignition PresstheON OFFkeys simultaneously thealarmwillsound3Beepsconfirmingtherecordin...

Page 4: ...cret Button required to be enabled by master TW10 only ATTENTION Inthiscase itwillnotbepossibletocancelthetriggeringbythecontrol Operation With the ignition on and the doors closed press the master key for 1 second Otherwise Secret Button Lock will be enabled After the programmed time according to the Beep 7 setting the ultrasound LED starts blinking the audio system will be turned off the siren an...

Page 5: ... the sensors to the vehicle s windshield 10cm below the roof Ultrasound Sensors come with digital sensitivity adjustment Only change the default setting if necessary Follow the table below Holdthemasterpresseduntilbeep9 SetUltrasoundSensitivity Withthedooropen turnheignitionon Thealarmwillrespondinformingthecurrentsetting 3Beeps SensitivitySTANDARD 2Beeps Sensitivity 10 4Beeps Sensitivity 10 5Beep...

Page 6: ...indows Connect the Green Black wireofthealarm tothe Brown Greenwireofthe6 wayharness oftheoriginalalarm locatedat thesteering column 9 3 FIAT Mode Palio Idea Punto and Linea with automated power windows up and down Connect the Green Black alarm wire to pin 8 on the original switch to the Palio and Idea line located behind the glove box OnLineaandPunto Red Blackwireintheswitchlocatedbehindthefusebo...

Page 7: ...Lock activation 5 Beeps VW UP With the door open turn the ignition on Hold the master pressed until beep 8 The alarm will respond informing 1 Beep Universal 2 Beeps VW G5 3 Beeps FIAT 6 Beeps MOBI 4 Beeps VW G6 EachpressontheMaster thealarmconfirmswith1beep Afterturning theignitionoff the alarmwillconfirmthenewsettingwith4beeps Tochangeit presstheMasterkey4times referringtotheVWG6 G7signal Attention ...

Page 8: ...nd will flash the TURNING LIGHTS for 45 seconds After 5 seconds it will go back to monitoring the sensors After 4 triggerings by the same sensor it will be canceled keeping the others active It will only be monitored again when the alarm is reset by the remote control Toinstallondoorswitch hoodortrunkwithPositivesignalwhenopen 2 ReadsPositiveswitch Itisusedtoopenelectricwindows forexample 1 ReadsNe...

Page 9: ...nute 2 beeps starts in 2 minutes 3 beeps starts in 3 minutes 6 ANTI THEFT BY SECRET BUTTON item 6 1 beep ENABLE 2 beeps DISABLE 4 AUTOMATIC LOCK item 11 3 1 beep ENABLE 2 beeps DISABLE 2 On Off BEEP 1 beep ENABLE 2 beeps DISABLE 8 SIGN FOR ORIGINAL WINDOW LOCK 1 item 9 1 beep UNIVERSAL 2 beeps VW G5 3 beeps FIAT 4 beeps VW G6 e G7 5 beeps VW UP only locking and unlocking 6 beeps MOBI config availabl...

Page 10: ...Negative door switch 2 Red Yellow LOCK 1 Black Yellow Dedicated Siren 1 Red 12Vcc 3 Black GND 4 Green Black Turning Lights 4 Green Black Turning Lights 9 Brown 10 Green Black Output to power window closing modules Auxiliary Output Config Beep 10 1 Negative Switch 2 Positive Switch 4 Auxiliary Output Config Beep 8 Mode VW G6 G7 and UP 11 Red Black UNLOCK 12 Blue Ignition 15 Black White 14 Black ACC o...

Page 11: ...at Rua Abílio Daguano 274 Res Manoel Martins Alfredo Marcondes SP ZIP19 180 000 guarantees this product against design manufacturing assembly and or joint and several malfunctions due to design flaws that make it unsuitable or inappropriateforitsintendeduse foraperiodof24monthsfromthedateofpurchase Productsdamagedbyincorrectinstallation waterinfiltration tamperingbyunauthorizedindividuals Naturalw...

Reviews: