background image

Fabricado por / Manufactured by:

TARAMPS ELECTRONICS LTDA

CNPJ / TAX ID: 11.273.485/0001-03

R. João Silvério, 121• Res. Manoel Martins

Alfredo Marcondes - SP

Indústria Brasileira - Made in Brazil

Taramps  reserves  the  right  to  change  the  contents  of  this  manual  without  prior  notice  or  obligation  to  apply 

modifications to previously produced units.

 Factory technical assistance department:

Taramps Electronics

 - Rua: Abílio Daguano, nº 274 - Alfredo Marcondes - ZIP 19.180-000

Phone number(18) 3266-4050 / 99749-3391
E-mail: [email protected]

14

MN_013514_R01

WARRANTY TERM 

In the event of a defect within the warranty period, TARAMPS' liability is limited to repairing or replacing the device manufactured by it.

TARAMPS, located at Rua Abílio Daguano, 274 Res. Manoel Martins - Alfredo Marcondes - SP, ZIP19.180-000, guarantees this product 
against  design,  manufacturing,  assembly  and/or  joint  and  several  malfunctions  due  to  design  flaws  that  make  it  unsuitable  or 
inappropriate for its intended use, for a period of 24 months from the date of purchase.

• Products damaged by incorrect installation, water infiltration, tampering by unauthorized individuals;
• Natural wear components: such as battery;

• Cases where the product is not used under regular conditions;

•Equipment removal and reinstallation costs, as well as its transportation to the technical assistance post;
• Damage of any kind, resulting from problems with the product, as well as losses caused by discontinuation of use.

• Scratched or torn warranty seal;

• The product presents damage resulting from drops, impacts or the action of agents of nature (floods, lightning, etc.);

• malfunction  caused by accessories, modifications or equipment attached to the product;

Summary of Contents for Tarsafe TW10

Page 1: ...TW10 TW10 SB MANUAL AUTOMOTIVE ALARM Without Lock ...

Page 2: ...hts Output Lock Unlock and Auxiliary Outputs Sound control and dedicated Siren Configurable output for activating locks and original power windows 9 to 16 Volts 6 to 25 mA Max 20 A 2 x 70W with digital protection Max 200 mA ground signal Max 200 mA positive signal Universal Fiat Line VW G5 G6 G7 VW UP and Mobi 3 Composition BASIC ALARM OPERATION When turning on the alarm by remote control if the ve...

Page 3: ...A HolddowntheONandOFFkeys 3blinks lineG1toG34flashes lineG4andforward B ReleaseafterLEDgoesout C TheLEDwillflashinformingthenewcodesystem RegisterNEWcontrolintheAlarmCenter Itispossibletorecordupto4controls whenrecordingthe5ththefirstonewillbeerased PROCEDURE Withthedooropen switchontheignition Toexitsetup turnofftheignition PresstheON OFFkeys simultaneously thealarmwillsound3Beepsconfirmingtherecordin...

Page 4: ...cret Button required to be enabled by master TW10 only ATTENTION Inthiscase itwillnotbepossibletocancelthetriggeringbythecontrol Operation With the ignition on and the doors closed press the master key for 1 second Otherwise Secret Button Lock will be enabled After the programmed time according to the Beep 7 setting the ultrasound LED starts blinking the audio system will be turned off the siren an...

Page 5: ... the sensors to the vehicle s windshield 10cm below the roof Ultrasound Sensors come with digital sensitivity adjustment Only change the default setting if necessary Follow the table below Holdthemasterpresseduntilbeep9 SetUltrasoundSensitivity Withthedooropen turnheignitionon Thealarmwillrespondinformingthecurrentsetting 3Beeps SensitivitySTANDARD 2Beeps Sensitivity 10 4Beeps Sensitivity 10 5Beep...

Page 6: ...indows Connect the Green Black wireofthealarm tothe Brown Greenwireofthe6 wayharness oftheoriginalalarm locatedat thesteering column 9 3 FIAT Mode Palio Idea Punto and Linea with automated power windows up and down Connect the Green Black alarm wire to pin 8 on the original switch to the Palio and Idea line located behind the glove box OnLineaandPunto Red Blackwireintheswitchlocatedbehindthefusebo...

Page 7: ...Lock activation 5 Beeps VW UP With the door open turn the ignition on Hold the master pressed until beep 8 The alarm will respond informing 1 Beep Universal 2 Beeps VW G5 3 Beeps FIAT 6 Beeps MOBI 4 Beeps VW G6 EachpressontheMaster thealarmconfirmswith1beep Afterturning theignitionoff the alarmwillconfirmthenewsettingwith4beeps Tochangeit presstheMasterkey4times referringtotheVWG6 G7signal Attention ...

Page 8: ...nd will flash the TURNING LIGHTS for 45 seconds After 5 seconds it will go back to monitoring the sensors After 4 triggerings by the same sensor it will be canceled keeping the others active It will only be monitored again when the alarm is reset by the remote control Toinstallondoorswitch hoodortrunkwithPositivesignalwhenopen 2 ReadsPositiveswitch Itisusedtoopenelectricwindows forexample 1 ReadsNe...

Page 9: ...nute 2 beeps starts in 2 minutes 3 beeps starts in 3 minutes 6 ANTI THEFT BY SECRET BUTTON item 6 1 beep ENABLE 2 beeps DISABLE 4 AUTOMATIC LOCK item 11 3 1 beep ENABLE 2 beeps DISABLE 2 On Off BEEP 1 beep ENABLE 2 beeps DISABLE 8 SIGN FOR ORIGINAL WINDOW LOCK 1 item 9 1 beep UNIVERSAL 2 beeps VW G5 3 beeps FIAT 4 beeps VW G6 e G7 5 beeps VW UP only locking and unlocking 6 beeps MOBI config availabl...

Page 10: ...Negative door switch 2 Red Yellow LOCK 1 Black Yellow Dedicated Siren 1 Red 12Vcc 3 Black GND 4 Green Black Turning Lights 4 Green Black Turning Lights 9 Brown 10 Green Black Output to power window closing modules Auxiliary Output Config Beep 10 1 Negative Switch 2 Positive Switch 4 Auxiliary Output Config Beep 8 Mode VW G6 G7 and UP 11 Red Black UNLOCK 12 Blue Ignition 15 Black White 14 Black ACC o...

Page 11: ...at Rua Abílio Daguano 274 Res Manoel Martins Alfredo Marcondes SP ZIP19 180 000 guarantees this product against design manufacturing assembly and or joint and several malfunctions due to design flaws that make it unsuitable or inappropriateforitsintendeduse foraperiodof24monthsfromthedateofpurchase Productsdamagedbyincorrectinstallation waterinfiltration tamperingbyunauthorizedindividuals Naturalw...