SPECIFICATION REQUIREMENTS
Maximum Water Temperature 49°C (120°F)
Maximum Daytime working pressure 4.76 BAR (70 psi)
Minimum working pressure 1.7 BAR (25 psi)
Minimum system flow 0.06m3/hr
Maximum system flow 3.18m3/hr
If a pressure-reducing valve is required this may be ordered from Tapworks:
Quote
Part No. 800220
for
1
⁄
2
” or 15mm pipework
Quote
Part No. 800223
for
3
⁄
4
” or 22mm pipework
UNVENTED OR DIRECT SYSTEMS
Connection to the water softener should be made with 22mm or 28mm
copper pipe and not with flexible hoses supplied, to ensure that a
satisfactory flow rate is maintained. You will also require a suitably sized
bypass set and check valve. Full flow valves are recommended. Large
bore flexible hoses are available from Tapworks.
DRAIN HOSE
We recommend that the maximum length of drain line is 3 feet before
entering an air gap. Also any rise in height of the drain should not be
above 3 feet.
CENTRAL HEATING SYSTEMS
Central heating systems should always be treated with a proprietary
corrosion inhibitor regardless of being filled with softened or hard water.
Systems containing aluminium should always be filled with hard water
unless instructed otherwise by the manufacturer.
Installation of Your Water Softener
(cont)
5
Please Remember
– Only use Tablet or Pellet Salt in Your Softener!
A
Pressure Reducing Valve
(if required)
B
Bypass Valve
C
Inlet Valve
D
Outlet Valve
A
B
C
D