5. CONVERT OVEN BURNER ORIFICE
FOR LP GAS
1. Remove storage drawer if equipped or lower panel to
gain access to oven burner spuds.
2. Remove oven bottom and oven burner baffle located on
top of burner. To remove oven bottom. Pull up at rear, dis-
engage front of oven bottom from oven front frame, and
pull the oven bottom straight out of the oven. Remove
burner baffle so that the burner flame can be observed.
3. Using 1/2" wrench, turn down the adjustable spud which
injects gas into the oven burner, until snug against the LP
metering pin. This will be approximately 2-1/2 turns.
Do
not overtighten.
4. Push the BAKE TEMP button, then SET the temperature
to 300°F. Wait until burner starts to cycle. To determine if
the oven burner flame is proper, observe the flame. It
should be steady with approximately 1" blue cones and no
yellow or orange flame tips.
5. If adjustment to the air shutter is necessary, locate oven
burner air shutter, loosen shutter set screw and adjust to ob-
tain optimum flame. This will normally be completely open
for LP gas. Tighten shutter set screw.
PIN
NAT
L.P.
AIR SHUTTER
OVEN BURNER SPUD
3. Lower main top and apply gas to check for proper flame
size. Flame should be steady with approximately 1/2" blue
inner cones and no yellow or orange tips.
PROPER AIR ADJUSTMENT
If the air shutter is adjusted so that too much air flows into
the burner, the flame will appear unsteady, possibly not
burning all the way around and will be noisy (like a blow
torch).
3. READJUST THE “LOW” SETTING
SURFACE BURNER VALVE
1. Turn control to LITE until burner ignites.
2.
Quickly
turn knob down to LOWEST SETTING.
3. If burner goes out, readjust valve as follows:
(as described in installation Step No. 6, from page 5).
4. AIR ADJUSTMENT SHUTTER
Apply gas to the burner and adjust air shutter on burner ven-
turi tube to proper flame. For LP gas, the air shutter is gen-
erally left completely open.
The air adjustment for each of the four burners is located at
the open end of the venturi tube and sits on the hood of the
valve. The shutter is held in place by friction fit.
If the air shutter needs adjusting, rotate the shutter to allow
more or less air into the burner tubes as needed.
6
SPUD
1
/
2
"
INNER CONE FLAME LENGTH
Air adjustment shutter