1.
INSTALLATION
Steinle Filter Press Pump Series
12
To facilitate the operation of the pump we recommend an air treatment system connected to
the air supply. These components should be included:
1) Regulator to adjust the air pressure;
2) Manometer to read the actual pressure;
3) Needle valve to adjust the air flow (especially when operating the pump in the lower range
of performance);
4) Filter.
These components are included in Tapflo’s
Air treatment system
which can be ordered from
us.
1.8.2.
Air quality classes
ISO 8573-1:2010 Compressed Air Contaminants and Purity Classes
Class
Solid particles
Water
Oil
Maximum number of particles
per m³
Mass
concentration
[mg/m³]
Pressure
dew point
[°C]
Liquid
[g/m³]
Total oil content
(liquid, aerosol and
vapour)
[mg/m³]
0.1 – 0.5
µm
0.5 – 1
µm
1 – 5 µm
0
As specified by the equipment user or supplier and more stringent than class 1
1
≤ 20,000
≤ 400
≤ 10
−
≤ −70
−
0.01
2
≤ 400,000
≤ 6,000
≤
100
−
≤ −40
−
0.1
3
−
≤ 90,000
≤ 1,000
−
≤ −20
−
1
4
−
−
≤ 10,000
−
≤ +3
−
5
5
−
−
≤ 100,000
−
≤ +7
−
−
6
−
−
−
≤ 5
≤ +10
−
−
7
−
−
−
5 – 10
−
≤ 0.5
−
8
−
−
−
−
−
0.5 – 5
−
9
−
−
−
−
−
5 – 10
−
X
−
−
−
> 10
−
> 10
> 10