5. DATA
Steinle Filter Press Pump Series
60
5.5.
Tightening torques
Checking of the tightening torques is necessary after all periods of stoppage, when
temperature variations are a factor and after all transport and maintenance of the pump.
What is more for proper operation and safety the torque values should be checked frequently
as part of preventive maintenance (please contact Tapflo for interval proposals).
FP25/40 CS/SS
F25/40 PP
Position
Moment of
force [Nm]
Position
Moment of
force [Nm]
Top housing - manifold bolt
80
Top housing - manifold
bolt
35
Bottom housing - manifold
bolt
15
Bottom housing -
manifold bolt
15
Housing - housing bolt
80
Housing - housing bolt
80
-
-
Manifold - manifold bolt
35
FP50/80 CS/SS
FP50/80 PP
Position
Moment of force
[Nm]
Position
Moment of force
[Nm]
Top housing - manifold bolt
80
Top housing - manifold bolt
35
Bottom housing - manifold bolt
25
Bottom housing - manifold
bolt
25
Housing - housing bolt
160
Housing - housing bolt
160
-
-
Manifold - manifold bolt
35
Summary of Contents for Steinle Filter Press Pump Series
Page 58: ...5 DATA Steinle Filter Press Pump Series 58...
Page 65: ......