Release 7/2009 Ver. 1.0
Technical Manual: GS-120 Light Curtain Systems
TAPESWITCH CORPORATION
Phone: 631-630-0442
100 Schmitt Boulevard
30
Fax: 631-630-0454
Farmingdale, New York 11735
www.tapeswitch.com
Figure 35 – Manual Restart with EDM
3.3.3.3 SSR Version
This version has two voltage-free solid-state outputs. It
operates in automatic mode, so the outputs will be on
whenever the curtain is clear and off whenever the
curtain is obstructed. See
Figure 36.
Figure 36 – SSR Version Wiring
Ground