Release 7/2009 Ver. 1.0
Technical Manual: GS-120 Light Curtain Systems
TAPESWITCH CORPORATION
Phone: 631-630-0442
100 Schmitt Boulevard
52
Fax: 631-630-0454
Farmingdale, New York 11735
www.tapeswitch.com
JUMPERS
For ONE Light Curtain
Jumper 1 to 2, 4 to 9
Jumper 1 to 2, 7 to 8
(if not used)
For TWO Light Curtains
5 to 14, and 7 to 8
(if not used)
19 to 20
(if not used)
Figure 54 - Input and Output Functions, Jumper Details and
Terminal Numbers for the BSRUA-2
26
27
28
Live
Ground
Neutral
AC Power Input
2
3
+24V DC
OV DC
DC Input Power
FOR AC POWER
110VAC: Jumper 29 to 31 and 30 to 32
240VAC: Jumper 30 to 31
Redundant
Safety Outputs
N/O
Output 1
N/O
Output 2
24
23
22
21
Test Inputs (if used)
7
8
19
20