6. Monitor Parameters & EQ Facilities
Monitor Parameters
In order to access the Monitor parameters & EQ facilities page, see Fig. 11; click once on any monitor
on the network in the main page you would like to EQ or select a monitor from the drop down menu
and press the
<Edit>
button.
Fig.11.
Monitor parameters window
The monitor parameters that may be adjusted in this window are:
<Polarity 180 deg>
This function is only available on the subwoofer. Check the box to reverse the polarity
of the subwoofer.
<Lck >
This facility disables the
Polarity 180 deg
option in case of accidental activation.
If locked the no alteration is possible from the master monitor or iDP SOFT
TM
.
<LFE>
Mark this box to activate the Low pass filter. Again this function is only available
on the subwoofer.
<Room Position>
Assuming that no RTA measurement system is being used you can set the position
in the room of each respective monitor using the drop down menu. There is an
<Lck>
(Lock) facility to disable the
room position facility
in case of
accidental activation. If locked the no alteration is possible from the master monitor
or iDP SOFT
TM
.
The monitor room positions available for selection are:
Neutral
– freestanding away from boundaries
Wall
– against a wall i.e. one boundary
Corner
– in a corner i.e. two boundaries
Console
– located above console in very close proximity
Console Wall
– above console against a wall
Console Corner
– above console in corner
17