Adjusting ZONE1 Set Point (SP1)
Press / release the PGM button to advance to the
'SP1' entry screen (as indicated in the TEMPERATURE
display window)
Press the UP/DOWN buttons to adjust SP1 to the
desired value (as shown in the SETPOINT display
window)
Adjusting ZONE2 Set Point (SP2)
Press / release the PGM button to advance to the
'SP2' entry screen (as indicated in the TEMPERATURE
display window)
Press the UP/DOWN buttons to adjust SP2 to the
desired value (as shown in the SETPOINT display
window)
Adjusting SP1 and SP2 - Simultaneously
Press and
hold
the PGM button.
While holding the PGM button depressed, use the UP
and DOWN buttons to adjust SP1 to the desired value
(as indicated in the SETPOINT window). The value of
SP2 also changes by this same amount, despite the
fact that is is not visable during adjustment.
Note:
Holding down the UP or DOWN button while
making adjustments will ramp the value accordingly.